Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

نویسندگان

  • Ronald K Binder
  • Jonathon Leipsic
  • David Wood
  • Teri Moore
  • Stefan Toggweiler
  • Alex Willson
  • Ronen Gurvitch
  • Melanie Freeman
  • John G Webb
چکیده

BACKGROUND Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities, including multidetector computed tomography (MDCT), have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3-dimensional angiographic reconstructions (3DA) of the aortic root for prediction of the optimal deployment angle and compared it with MDCT. METHODS AND RESULTS Forty patients undergoing transfemoral TAVR at St Paul's Hospital, Vancouver, Canada, were evaluated. All underwent preimplant 3DA and 68% underwent preimplant MDCT. Three-dimensional angiographic reconstructions were generated from images of a C-arm rotational aortic root angiogram during breath-hold, rapid ventricular pacing, and injection of 32 mL contrast medium at 8 mL/s. Two independent operators prospectively predicted perpendicular valve projections. The implant angle was chosen at the discretion of the physician performing TAVR. The angles from 3DA, from MDCT, the implant angle, and the postdeployment perpendicular prosthesis view were compared. The shortest distance from the postdeployment perpendicular prosthesis projection to the regression line of predicted perpendicular projections was calculated. All but 1 patient had adequate image quality for reproducible angle predictions. There was a significant correlation between 3DA and MDCT for prediction of perpendicular valve projections (r=0.682, P<0.001). Deviation from the regression line of predicted angles to the postdeployment prosthesis view was 5.1±4.6° for 3DA and 7.9±4.9° for MDCT (P=0.01). CONCLUSIONS Three-dimensional angiographic reconstructions and MDCT are safe, practical, and accurate imaging modalities for identifying the optimal perpendicular valve deployment projection during TAVR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pre-procedural imaging of aortic root orientation and dimensions: comparison between X-ray angiographic planar imaging and 3-dimensional multidetector row computed tomography.

OBJECTIVES We sought to examine whether contrast-enhanced multidetector row computed tomography (MDCT) allows prediction of X-ray angiographic planes for the root angiogram in the context of transcatheter aortic valve implantation. BACKGROUND Understanding of aortic root orientation relative to the body axis is critical for precise positioning of the stent/valve during transcatheter aortic va...

متن کامل

Multislice computed tomography for prediction of optimal angiographic deployment projections during transcatheter aortic valve implantation.

OBJECTIVES This study assessed whether multislice computed tomography (MSCT) could predict optimal angiographic projections for visualizing the plane of the native valve and facilitate accurate positioning during transcatheter aortic valve implantation (TAVI). BACKGROUND Accurate device positioning during TAVI depends on valve deployment in angiographic projections perpendicular to the native...

متن کامل

Integrated 3D Echo-X-Ray navigation to predict optimal angiographic deployment projections for TAVR.

(A) The integrated marking feature allows for the placement of a colored are placed on or near the center of each of the coronary cusps in the en colored markers are individually dragged (table side control, using a stand level of the aortic annulus (left panel). These 2 separate steps result in the (long-axis location) of each coronary cusp of the native aortic valve. (C) to a position such th...

متن کامل

Assessment of the aortic root using real-time 3D transesophageal echocardiography.

BACKGROUND Precise evaluation of the aortic root geometry prior to transcatheter aortic valve implantation is important for procedural success in patients with aortic stenosis (AS). To determine the potential for 3-dimensional transesophageal echocardiography (3DTEE), the aims of the present study were: (1) to assess the accuracy of 3DTEE measurements of the aortic root using multidetector comp...

متن کامل

Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement.

BACKGROUND Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. METHODS AND RESULTS Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Cardiovascular interventions

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 2012