Pulse-Doppler Ultrasound and Its Clinical Application

نویسندگان

  • Peter Atkinson
  • Peter N.T. Wells
چکیده

Doppler devices can provide clinically useful information about blood flow. This paper describes how a pulse-Doppler instrument has been linked to a B-scan machine so that flow patterns in any ultrasonically accessible vessel can be monitored from the skin surface. The same transducer is used for both modes of investigation to enable accurate and reliable positioning of the sample-volume. After briefly summarizing the principles of continuous-wave and pulse-Doppler operation, the concepts and relative advantages of coherent and non-coherent detection are explained. The potential clinical uses of the pulse-echo-Doppler hybrid and Doppler devices in general are then discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulse Doppler Analysis in External Ophthalmic and the Long Ciliary Ophthalmic Arteries in the Cat

Objective- Analysis of the PSV (peak systolic velocity), EDV (end diastolic velocity) and RI (Resistant Index) in external ophthalmic and the long ciliary ophthalmic arteries in the cat by pulse Doppler. Design- Descriptive study Animals- 12 short haired “Tomcats” weighted about 3.9± 0.9 Kg no e general and optic disease in clinical, paraclinical and ophthalmoscopic examinations. Pr...

متن کامل

برآورد سرعت موج پالس با استفاده از پارامترهای شریانی استخراج شده از تصاویر فراصوتی کاروتید

  Background & Objective : Several indices have been introduced to estimate arterial stiffness that based on changes in brachial blood pressure. But because of the error resulted by the substitution of brachial blood pressure instead of the other central arteries, such as carotid, it will be very important to present elastic parameter based on the mechanical models without any emphasis on brach...

متن کامل

Heart Rate Assessment Immediately after Birth.

BACKGROUND Heart rate assessment immediately after birth in newborn infants is critical to the correct guidance of resuscitation efforts. There are disagreements as to the best method to measure heart rate. OBJECTIVE The aim of this study was to assess different methods of heart rate assessment in newborn infants at birth to determine the fastest and most accurate method. METHODS PubMed, EM...

متن کامل

Extending the Radar Dynamic Range using Adaptive Pulse Compression

The matched filter in the radar receiver is only adapted to the transmitted signal version and its output will be wasted due to non-matching with the received signal from the environment. The sidelobes amplitude of the matched filter output in pulse compression radars are dependent on the transmitted coded waveforms that extended as much as the length of the code on both sides of the target loc...

متن کامل

Why Current Doppler Ultrasound Methodology Is Inaccurate in Assessing Cerebral Venous Return: The Alternative of the Ultrasonic Jugular Venous Pulse

Assessment of cerebral venous return is growing interest for potential application in clinical practice. Doppler ultrasound (DUS) was used as a screening tool. However, three meta-analyses of qualitative DUS protocol demonstrate a big heterogeneity among studies. In an attempt to improve accuracy, several authors alternatively measured the flow rate, based on the product of the time average vel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Yale Journal of Biology and Medicine

دوره 50  شماره 

صفحات  -

تاریخ انتشار 1977