Deep inspiration breath‐hold technique guided by an opto‐electronic system for extracranial stereotactic treatments
نویسندگان
چکیده
The purpose of this work was to evaluate the intrapatient tumor position reproducibility in a deep inspiration breath-hold (DIBH) technique based on two infrared optical tracking systems, ExacTrac and ELITETM, in stereotactic treatment of lung and liver lesions. After a feasibility study, the technique was applied to 15 patients. Each patient, provided with a real-time visual feedback of external optical marker displacements, underwent a full DIBH, a free-breathing (FB), and three consecutive DIBH CT-scans centered on the lesion to evaluate the tumor position reproducibility. The mean reproducibility of tumor position during repeated DIBH was 0.5 ± 0.3 mm in laterolateral (LL), 1.0 ± 0.9 mm in anteroposterior (AP), and 1.4 ± 0.9 mm in craniocaudal (CC) direction for lung lesions, and 1.0 ± 0.6 mm in LL, 1.1 ± 0.5 mm in AP, and 1.2 ± 0.4 mm in CC direction for liver lesions. Intra- and interbreath-hold reproducibility during treatment, as determined by optical markers displacements, was below 1 mm and 3 mm, respectively, in all directions for all patients. Optically-guided DIBH technique provides a simple noninvasive method to minimize breathing motion for collaborative patients. For each patient, it is important to ensure that the tumor position is reproducible with respect to the external markers configuration.
منابع مشابه
A Comparative Study of 3-D Conformal Radiotherapy Treatment Plans with and Without Deep Inspiration Breath-Hold Technique for Left-Sided Breast Cancer
Introduction: The rate of cardiac diseases have increased among patients who underwent radiotherapy for left-sided breast cancer. The study’s aim was evaluate the dose to organs at risk in free-breathing 3-dimensional conformal (FB-3DCRT) against 3-dimensional conformal deep inspiration breath-hold (3DCRT-DIBH) in patients with left-sided breast cancer. Ma...
متن کاملA gated deep inspiration breath‐hold radiation therapy technique using a linear position transducer
For patients with thoracic and abdominal lesions, respiration-induced internal organ motion and deformations during radiation therapy are limiting factors for the administration of high radiation dose. To increase the dose to the tumor and to reduce margins, tumor movement during treatment must be minimized. Currently, several types of breath-synchronized systems are in use. These systems inclu...
متن کاملChallenges of maintaining breath-hold conformity for breast patients while using the deep inspiration breath-hold technique
Deep inspiration breath-hold (DIBH) is used for whole breast radiotherapy, as a means of providing better dose homogeneity. This can be achieved by lower doses to the organs at risk, less patient movement and better set up. Most patients offered DIBH treatment are left-sided breast cancer, or ductal carcinoma in situ (DCIS) patients, due to the proximity of the heart to the chest wall so it is ...
متن کاملDevelopment of a deep inspiration breath‐hold system for radiotherapy utilizing a laser distance measurer
Deep inspiration breath-hold (DIBH) is a technique for treating left-sided breast cancer (LSBC). In modern radiotherapy, one of the main aims is to exclude the heart from the beam aperture with an individualized beam design for LSBC. A deep inhalation will raise the chest wall while the volume of the lungs increase, this will again push the heart away from the breast to be treated. There are a ...
متن کاملSingle 20-second acquisition of deep-inspiration breath-hold PET/CT: clinical feasibility for lung cancer.
UNLABELLED This study was designed to compare tumor (18)F-FDG uptake between a single 20-s acquisition of deep-inspiration breath-hold PET/CT and free-breathing PET/CT for lung cancer. METHODS Before the clinical study, a phantom study was performed to determine the optimum breath-hold time for the PET scan. We studied 47 patients with lung cancer who underwent free-breathing PET/CT with the ...
متن کامل