Two decades of transesophageal phased array probes.
نویسندگان
چکیده
After its introduction about two decades ago, transesophageal echocardiography (TEE) has rapidly evolved into an important diagnostic feature for the cardiologist, since it offers anatomic and hemodynamic information which cannot be obtained precordially. Part of this success was due to the developments in transducer technology which resulted in smaller probes with progressively better imaging qualities. A short review of past, recent and future developments of TEE phased array probes, in particular those at the Erasmus University in Rotterdam, will be given. Furthermore, this article discusses basic parameters of the transducer dictating image quality such as centre frequency, array aperture and focusing illustrated with several simulations. The simulations show that a poor design of the transducer will limit the resolution and will give artefacts in the two-dimensional image.
منابع مشابه
Three-dimensional Echocardiography in the Assessment of Prosthetic Valves Ecocardiografı́a tridimensional en la evaluación de las válvulas protésicas
Over the past few decades, transesophageal echocardiography (TEE) has evolved from one-dimensional imaging using a probe with a single-crystal, M-mode transducer to two-dimensional imagingwith phased-array transducers and now three-dimensional (3D) imaging with matrix array transducers. Current 3D imaging probes are vastly superior to the earlier technique of using multi-plane TEE imaging to re...
متن کاملMiniaturized Phased-Array Ultrasonic Endoscope Initial Experience With Intracardiac Imaging in Piglets
Background. Recent advances in miniaturization of phased-array and mechanical ultrasound devices have resulted in exploration of alternative approaches to cardiac and vascular imaging in the form of transesophageal or intravascular imaging. Preliminary efforts in adapting phased-array endoscopes designed for transesophageal use to a transvascular approach have used full-sized phased-array devic...
متن کاملTransvascular intracardiac applications of a miniaturized phased-array ultrasonic endoscope. Initial experience with intracardiac imaging in piglets.
BACKGROUND Recent advances in miniaturization of phased-array and mechanical ultrasound devices have resulted in exploration of alternative approaches to cardiac and vascular imaging in the form of transesophageal or intravascular imaging. Preliminary efforts in adapting phased-array endoscopes designed for transesophageal use to a transvascular approach have used full-sized phased-array device...
متن کاملThree-dimensional echocardiography in the assessment of prosthetic valves.
Over the past few decades, transesophageal echocardiography (TEE) has evolved from one-dimensional imaging using a probe with a single-crystal, M-mode transducer to two-dimensional imagingwith phased-array transducers and now three-dimensional (3D) imaging with matrix array transducers. Current 3D imaging probes are vastly superior to the earlier technique of using multi-plane TEE imaging to re...
متن کاملPhased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test
One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ultrasound in medicine & biology
دوره 22 1 شماره
صفحات -
تاریخ انتشار 1996