Detection of Subclinical Synovial Inflammation by Microwave Radiometry

نویسندگان

  • Evangelia Zampeli
  • Ioannis Raftakis
  • Archontoula Michelongona
  • Chara Nikolaou
  • Antonia Elezoglou
  • Konstantinos Toutouzas
  • Elias Siores
  • Petros P. Sfikakis
چکیده

OBJECTIVE Microwave Radiometry is a non-invasive method which determines within seconds the in vivo temperature of internal tissues at a depth of 3-7 cm with an accuracy of ±0.2°C. In this proof-of-concept study, we tested the hypothesis that, in absence of relevant clinical signs, increased local temperature detected by microwave radiometry reflects subclinical synovial inflammation, using ultrasound as reference method. METHODS Knees of healthy controls, subjects with recent knee trauma and symptom-free patients with rheumatoid arthritis (RA) or osteoarthritis were examined by placing the microwave radiometry sensor, a) at the upper one third of the anterior surface of the thigh (control-point), and b) over the suprapatellar recess. Ultrasound was performed immediately after and the possible presence of fluid and/or synovitis was correlated with microwave radiometry findings. RESULTS In 30 healthy and 10 injured knees the temperature was always lower than thigh (32.3±1.1 and 31.8±1.4 versus 34.1±0.9 and 33.6±1.2°C with a difference (ΔΤ) of -1.8±0.2 and -1.9±0.4°C respectively). Of 40 RA and 20 osteoarthritis knees examined, ultrasound findings indicative of subclinical inflammation (fluid effusion and/or Doppler signal) were found in 24 and 12, respectively, in which the temperature was higher than healthy knees and ΔΤ was lower (-0.9±0.7 in RA and -1.0±0.5 in osteoarthritis versus -1.8±0.2°C, p<0.001). The 5 RA knees with power Doppler findings indicative of grade 2 inflammation had a ΔΤ 3 times lower compared to healthy (-0.6±0.6, p = 0.007), whereas the 9 RA and the 7 osteoarthritis knees with additionally fluid effusion, had even lower ΔΤ (-0.4±0.7, p<0.001). CONCLUSION Using a safe, rapid and easy-to-perform method, such as microwave radiometry, thermal changes within the knee joint may reflect non-clinically apparent joint inflammation. Refinement of this method, including production of sensors for small joints, could result to the development of the ideal objective tool to detect subclinical synovitis in clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using microwave radiometry for detection of breast cancer

It should be noted that thermal changes precede to the anatomical changes that can be detected by traditional methods such as ultrasonography, mammography and palpation. Thus microwave radiometry is a very promising method for the breast cancer detection at an earlier stage. Also it should be noted that as microwave radiometry measures natural electromagnetic radiation from the patient’s tissue...

متن کامل

Applied Physics – Medical Physics Microwave Thermography for Cancer Detection

The paper presents some new methods for early breast cancer detection using microwaves. On describe the following methods and techniques: microwave impedance tomography, termography and microwave radiometry, combined methods microwave and ultra-acustic image and confocal microwave imaging. We make an analysis of advantages and disadvantages of every method and also physical principles of microw...

متن کامل

Visibility of breast malignancy by microwave radiometry: preliminary results on a real antenna

In microwave radiometry for early detection of breast malignancy a contacting antenna is scanned on the breast surface, while a pressure is exercised along with a deformation. Assuming the antenna at lower temperature than the breast, the results of a numerical modeling show an interesting increase in tumor radiometric visibility in compressed breast. Preliminary results on a real radiometric a...

متن کامل

Morphological and functional assessment of carotid plaques have similar predictive accuracy for coronary artery disease.

BACKGROUND AND PURPOSE Microwave radiometry allows noninvasive in vivo measuring of internal temperature of tissues reflecting inflammation. In the present study, we evaluated the predictive accuracy of this method for the diagnosis of coronary artery disease (CAD). METHODS Consecutive patients (n=287) scheduled for coronary angiography were included in the study. In carotid arteries of both ...

متن کامل

Microwave Radiometry Imaging for Forest Fire Detection: a Simulation Study

This paper deals with passive microwave imaging for fire detection by means of a single-channel ground-based radiometer. The simulation of images sensed in the presence of fire spots under different environmental and operative conditions will be presented. We will refer to a low-cost ground-based radiometer operating at 12.65GHz. Scenarios where fires are un-visible and IR sensors are not usefu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013