Optical performance of the cornea six years following photorefractive keratectomy for myopia.
نویسندگان
چکیده
PURPOSE To investigate the optical quality of the anterior cornea during a 6-year follow-up after photorefractive keratectomy (PRK) for myopia. METHODS Forty-nine patients (98 eyes) underwent PRK using an excimer laser platform. Patients were subdivided into three groups according to their preoperative spherical equivalent refraction and amount of cylinder component: the low-myopia, the high-myopia, and the astigmatism group. Preoperative and 1-, 3-, and 6-year postoperative root-mean-square values of coma, spherical aberration (SA), and total high-order aberrations (HOA) were calculated over 3.50- and 6.00-mm pupil diameters. Modulation transfer function (MTF) values and point spread functions were calculated to describe the impact of myopic PRK on the optical performance of the cornea during follow-up. RESULTS The amount of postoperative SA was higher (P < 0.05) than the preoperative state in both the low- and the high-myopia groups over 3.50- and 6.00-mm pupil sizes. The postoperative increase of coma was statistically significant (P < 0.05) only in the high-myopia group over both pupil sizes. Total-HOA increased (P < 0.05) after PRK in all the study groups over 6.00-mm pupil. A distinct increase in the ratios of MTF was calculated over 6.00-mm pupil, at low and middle spatial frequencies in the range between 5 and 15 cyc/deg, especially after the deepest myopic ablations. CONCLUSIONS The high-order wavefront aberration of the anterior cornea stabilized 1-year after PRK for the treatment of myopia up to -9.00 D. The effect of induced HOA on the image optical quality of the cornea was increased mainly after the correction of high myopia over scotopic pupil.
منابع مشابه
نتایج عمل Photorefractive keratectomy برای درمان نزدیک بینی زیاد در کلینیک نور تهران
Many studies have shown the effectiveness of photorefractive keratectomy (PRK) in correction of vision in low and moderate Myopia. To evaluate the results of 193-nm exeimer laser photorefractive keratectomy for highly Myopic eyes, we reviewed refractive outcome of 43 eyes of 30 patients. Most eyes were treated with 1-step operation, using a 6 mm optical zone. 43 eyes were treated for Myopia, wh...
متن کاملLong-term changes of the anterior corneal topography after photorefractive keratectomy for myopia and myopic astigmatism.
PURPOSE To analyze the anterior corneal topography changes after 8 years after photorefractive keratectomy (PRK) for the correction of myopia and myopic astigmatism. METHODS Sixty-six eyes (33 patients) underwent PRK using an excimer laser platform. Patients were subdivided into three groups: the low myopia (13 patients; range, -1.25 to -4.40 diopters [D]), the high myopia (13 patients; -4.50...
متن کاملCorneal transparency and measurement of corneal permeability in excimer laser photorefractive keratectomy.
PURPOSE To introduce an image analysis of the cornea in photorefractive keratectomy (PRK) for preoperative and early postoperative determination of changes in the condition of the cornea. METHODS Slit-lamp videography was used to evaluate the cornea. Microdensitometry of the corneal images was performed. The optic density of the anterior, middle, and posterior corneal layers was measured. Pho...
متن کاملTherapeutic alloplastic laser in situ keratomileusis for myopia.
BACKGROUND A new technique, therapeutic alloplastic laser in situ keratomileusis to correct high myopia, is introduced. METHODS Therapeutic alloplastic laser in situ keratomileusis consists of neutral homoplastic epikeratoplasty combined with superficial keratectomy performed with an excimer laser and/or a microkeratome. Indications for the technique are: myopia over 20 diopters (D), eyes wit...
متن کاملVisual performance after excimer laser photorefractive keratectomy for high myopia
PURPOSE To evaluate the efficacy, safety, predictability, and visual performance of excimer laser photorefractive keratectomy (PRK) for myopia greater than -8 diopters (D). METHODS Fifty-four patients (104 eyes) with myopia from -8D to -13D and cylinder up to -4D received surface ablation technique with the Allegretto wave version 1009-1 excimer laser to correct their refractive error. The pa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 52 2 شماره
صفحات -
تاریخ انتشار 2011