Ventilation effects on humidity measurements in thermometer screens
نویسندگان
چکیده
Relative humidity (RH) measurements, as derived from wet-bulb and dry-bulb thermometers operated as a psychrometer within a thermometer screen, have limited accuracy because of natural ventilation variations. Standard RH calculations generally assume a fixed screen psychrometer coefficient, but this is too small during poor ventilation. By comparing a reference humidity probe—exposed within a screen containing a psychrometer—with wind-speed measurements under controlled conditions, a wind-speed correction for the screen psychrometer coefficient has been derived and applicable when 2-metre wind speeds fall below 3 ms – 1 . Applying this to hourly-averaged data reduced the mean moist RH bias of the psychrometer (over the reference probe) from 1.2% to 0.4%, and reduced the inter-quartile range of the RH differences from 2.0% to 0.8%. This correction is particularly amenable to automatic measurement systems.
منابع مشابه
Efficacy of a heated passover humidifier during noninvasive ventilation: a bench study.
BACKGROUND Noninvasive positive-pressure ventilation (NPPV) delivers air at a high flow, which is associated with airway mucosal drying and impaired airway functioning. OBJECTIVES To examine the effects of mechanical ventilation parameters on relative humidity and absolute humidity during NPPV, and to evaluate the effect of a heated passover humidifier on relative humidity, absolute humidity,...
متن کاملSimulated Effects of Various Environmental Management Practices on Water Consumption in Open and Confined Greenhouse Systems
The objective of this study was to evaluate the effects of relative humidity, light management, minimum ventilation rates, CO2 enrichment and canopy size on water consumption in three different greenhouse systems (conventional, open heat pump, and confined heat pump) in winter, spring, and summer months. Using different relative humidity set points resulted in almost the same relative humidity ...
متن کاملIndoor and Outdoor Air Fungus Bioaerosols in Khorramabad Day Care Child Centers Western of Iran, 2018
Introduction: the aim of this study was to determine the quantity and quality of indoor and outdoor air fungus bioaerosols in Khorramabad day care child centers. Materials and Methods: A total of 180 air samples were collected from 10 centers in 2018. The samples included 7 indoor and 2 outdoor sampling points. The total number of children was 580. Sampling of fungal bioaerosols was performed ...
متن کاملبررسی تماس شغلی با پارا فنیلن دی آمین ( PPD ) موجود در هوای استنشاقی آرایشگران زنانه شهر ساری و عوامل محیطی تاثیر گذار
Background and aims: Hairdressing because of using hair dyes, are exposed to PPD that endanger their health. Measuring the concentration of PPD is a sure way to evaluate the PPD facing rate. PPD causes leukemia and other blood disorders. PPD acute poisoning leads to respiratory distress, rhabdomyolysis, muscle necrosis and renal failure, severe edema of the face and neck, increased serum lactat...
متن کاملY-piece temperature and humidification during mechanical ventilation.
BACKGROUND Practitioners often presume there is adequate humidification in the ventilator circuit if the Y-piece is at a specified temperature, but control of Y-piece temperature may be inadequate to ensure adequate humidification. METHODS In an in vitro bench model we measured water-vapor delivery with several heated humidification setups and a wide range of minute volume (V (E)) values. The...
متن کامل