Fluorometric Determination of Vitamin Constituents in Human Plasma
نویسنده
چکیده
Methods: Alpha tocopherol, gamma tocopherol, and retinol are assayed using fluorescence detection. Excitation/emission wavelengths are 295 nm/330 nm and 325 nm/470 nm for the analysis of both tocopherols and retinol, respectively. Retinol acetate is employed as the internal standard. The reversed phase method incorporates gradient elution with a mobile phase consisting of methanol and acetonitrile. Separation of vitamin compounds is achieved using a bridged ethyl-hybrid C18 column.
منابع مشابه
A high-performance liquid chromatographic method for the determination of tocopherol in plasma and cellular elements of the blood.
A rapid sensitive, and reproducible procedure is described for the analysis of alpha-tocopherol in blood cells and plasma using high-performance liquid chromatography and fluorometric detection. The cardinal feature for the increased sensitivity of this high-performance liquid chromatographic procedure is that the fluorometric analysis was carried out at a short excitation wavelength (205 nm) w...
متن کاملLiquid-chromatographic determination of vitamin K1 in plasma, with fluorometric detection.
This assay for phylloquinone (vitamin K1) in plasma requires a single liquid-chromatographic step. Much smaller volumes of plasma (0.5-1.0 mL) are required than in previous assays. Before liquid chromatography, we purified crude lipid extracts by conventional chromatography on silica, then extracted the lipid fraction by dissolving it in an acidic mixture of hexane/acetonitrile (1/4 by vol) con...
متن کاملRapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma
A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...
متن کاملFluorometric determination of prostaglandins and thromboxane in plasma by high-performance liquid chromatography.
is a useful method. Although there have been some reports9~11) on the HPLC analysis of PGs and TX using 9-anthryldiazomethane (ADAM), these methods have less sensitivity than HPLC for the quantitative determination of PGs and TX in human plasma. The purpose of this investigation was to establish an HPLC method for the determination of PGs and TX in biological samples. For the analysis of PGs an...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کامل