Optimization and it's influence on value of doses in HDR and PDR brachytherapy.
نویسندگان
چکیده
The aim of this work is to examine the influence of the dose optimization procedure on the value of radiation doses in organs of risk and to compare value of doses measured in healthy tissues according to chosen different PDR brachytherapy (PDRBT) and HDR brachytherapy (HDRBT) fractionation schedule. Fifty one patients treated with PDRBT were qualified for calculations. This group included patients with head and neck cancer, brain tumor, breast cancer, sarcoma, penile cancer and rectal cancer. The doses were calculated in chosen critical points in surrounded healthy tissues. For all treatment plans the doses were compared with the use of the BED (Biologically Equivalent Dose) formula and PDR along with HDR values were calculated. Differences among total doses in PDRBT and different schemas of HDRBT in critical points before and after dose point and volume optimization, were analyzed. The same dependences were examined also for BEDs. One ascertained that in biologic equivalent (to PDR) HDRBT the increase of fraction dose from 4 Gy to 10 Gy caused the necessity of decrease of total dose in treatment area (p<0,001). The use of HDR instead of PDR essentially lowered physical and biological doses in examined organs of risk. In many examined critical points in organs of risk where biological equivalence dose in the treatment area was the same, one ascertained the decrease of total physical HDR dose according to the growth of the fraction dose. Similar dependences appeared also for biologically equivalent doses. The optimization process in PDRBT improved the dose homogeneity in the treatment area, but simultaneously induced unprofitable (essential statistically) increase of dose in some healthy organs of risk, what makes an increase risk for radiation-induced complications. The use of biologically equivalent HDRBT instead of PDRBT makes for the decrease of physical doses in the treatment area and the decrease of physical and biologically equivalent doses in healthy organs of risk.
منابع مشابه
Influence of length of interval between pulses in PDR brachytherapy (PDRBT) on value of Biologically Equivalent Dose (BED) in healthy tissues
PURPOSE Different PDR treatment schemas are used in clinical practice, however optimal length of interval between pulses still remains unclear. The aim of this work was to compare value of BED doses measured in surrounded healthy tissues according to different intervals between pulses in PDRBT. Influence of doses optimization on BED values was analyzed. MATERIAL AND METHODS Fifty-one patients...
متن کاملHyperfractionation of HDR brachytherapy – influence on doses and biologically equivalent doses in clinical target volume and healthy tissues
PURPOSE The aim of this work was to compare value of doses calculated in healthy tissues according to chosen different HDR brachytherapy (HDRBT) fractionation schemas with doses given once and twice daily. MATERIAL AND METHODS Fifty one patients with head and neck cancers, brain tumors, breast cancers, sarcoma, penile cancer and rectal cancer were qualified for calculations. Doses were calcul...
متن کاملA survey of quality control practices for high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy in the United Kingdom
PURPOSE A survey of quality control (QC) currently undertaken in UK radiotherapy centres for high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy has been conducted. The purpose was to benchmark current accepted practice of tests, frequencies and tolerances to assure acceptable HDR/PDR equipment performance. It is 20 years since a similar survey was conducted in the UK and the current ...
متن کاملRectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector
Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...
متن کاملMonte Carlo investigation on precise dosimetry of HDR breast brachytherapy with Accuboost
Introduction: Accuboost is a HDR brachytherapy system in early stages breast cancer treatment. This device provides a completely noninvasive procedure with parallel-opposed radiation from two immobilizing peripheral applicators that caused it a preferred option of modalities to choose. In most commercial treatment planning systems, tissues are considered as a simple water phan...