Echocardiographic reference ranges for normal cardiac Doppler data: results from the NORRE Study.
نویسندگان
چکیده
AIMS Reference values for Doppler parameters according to age and gender are recommended for the assessment of heart physiology, specifically for left ventricular (LV) diastolic function. In this study, we report normal reference ranges for Doppler parameters obtained in a large group of healthy volunteers. Echocardiographic data were acquired using state-of-the-art cardiac ultrasound equipment following Doppler acquisition and measurement protocols approved by the European Association of Cardiovascular Imaging. METHODS AND RESULTS A total of 449 (mean age: 45.8 ± 13.7 years) healthy volunteers (198 men and 251 women) were enrolled at the collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. A comprehensive echocardiographic examination was obtained from all subjects following predefined protocols. The majority of the Doppler diastolic parameters (e', E/e') as well as right ventricle systolic s' wave velocity were similar in men and women. Left ventricle s' wave velocity was higher in men than in women. E wave and e' were higher in younger subjects and decreased progressively in the older ones. E/e' ratio increased with ageing. Septal e' <8 cm/s was present in 19.7% of the subjects in the 40-60 year group and in 55% of those in the ≥60 year group. However, the cut-off value of average E/e' or lateral E/e' remained <15 or 13, respectively, in the majority of patients. CONCLUSION The NORRE study provides the reference values for the most useful Doppler parameters in the evaluation of heart physiology. These data highlight the need of using age-specific reference values especially for the diagnosis of LV systolic and diastolic dysfunction and for the estimation of LV filling pressures.
منابع مشابه
Normal Reference Ranges for Echocardiography: rationale, study design, and methodology (NORRE Study).
BACKGROUND Availability of normative reference values for cardiac chamber dimensions, volumes, mass, and function is a prerequisite for the accurate application of echocardiography for both clinical and research purposes. However, due to the lack of consistency in current echocardiographic 'reference values', their use for clinical decision-making remains questionable. AIMS The aim of the 'No...
متن کاملEchocardiographic reference ranges for normal cardiac chamber size: results from the NORRE study.
AIMS Availability of normative reference values for cardiac chamber quantitation is a prerequisite for accurate clinical application of echocardiography. In this study, we report normal reference ranges for cardiac chambers size obtained in a large group of healthy volunteers accounting for gender and age. Echocardiographic data were acquired using state-of-the-art cardiac ultrasound equipment ...
متن کاملNormal reference values for echocardiography: a call for comparison between ethnicities.
Doppler echocardiography has become the standard imaging modality for the assessment of heart valve disease severity and ventricular diastolic function. However, due to the variability in Doppler parameters according to age, it is mandatory to establish reference limits that define normality. Furthermore, differentiation between normal and abnormal diastolic function depends on the targeted pop...
متن کاملStudy of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat
Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...
متن کاملTwo-dimensional transthoracic echocardiographic normal reference ranges for proximal aorta dimensions: results from the EACVI NORRE study.
AIMS To report normal reference ranges for echocardiographic dimensions of the proximal aorta obtained in a large group of healthy volunteers recruited using state-of-the-art cardiac ultrasound equipment, considering different measurement conventions, and taking into account gender, age, and body size of individuals. METHODS AND RESULTS A total of 704 (mean age: 46.0 ± 13.5 years) healthy vol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European heart journal cardiovascular Imaging
دوره 16 9 شماره
صفحات -
تاریخ انتشار 2015