Evaluation of a reconstituted dried serum as a clinical chemistry standard in the abnormal range.

نویسندگان

  • B KLEIN
  • M WEISSMAN
چکیده

A lyophilized serum chemistry reference standard containing constituents in the “abnormal” range has been evaluated for use as a proficiency standard. The findings indicate that it is a satisfactory material for such use and as a reference standard, provided that it is used in accordance with the manufacturer’s directions. Interferences contributing to inaccurate results in the analysis of bilirubin, cholesterol, and uric acid are indicated and discussed. It is recommended that the standard be used for the preparation of calibration curves for bilirubin and uric acid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Freeze-dried cold kit for preparation of 99mtc-ciprofloxacin as an infection imaging agent

  Introduction: Radiolabeled antibiotics are being used for the specific diagnosis of infection by exploiting their specific binding properties to the bacterial components, thereby making it possible to differentiate infection from sterile lesions. The aim of this work was to prepare and evaluate a freeze-dried kit of ciprofloxacin designed for the labeling with ...

متن کامل

Determination of creatinine in serum and urine by a rapid liquid-chromatographic method.

We describe an HPLC ion-pair procedure for rapid and specific evaluation of creatinine in serum and urine. We used a 15 cm X 4.6 mm ODS column with a 50/50 (by vol) mixture of sodium decanesulfonic acid (10 mmol/L, pH 3.2) and methanol and measured absorbance at 236 nm. Serum (100 microL) or 30-fold-diluted urine (100 microL) was added to 400 microL of acetone. After centrifugation, the superna...

متن کامل

Serum Alpha-1-antitrypsin Evaluation by Three Electrophoretic, Enzymatic and Immunodiffussion Methods

Abstract Background & Objective: Alpha-1-antitrypsin (AAT) is the major component of the human plasma alpha-1 globulin proteins and acts as a major inhibitor of proteolytic enzymes, particularly elastase. AAT deficiency is accompanied by lung, liver and other disorders, therefore, AAT is clinically important and its precise evaluation is diagnostically critical. In present study serum AAT was e...

متن کامل

Evaluation of CT angiography findings in the patients with clinical diagnosis of pulmonary thromboembolism

Background and Aim: Pulmonary thromboembolism is an important clinical problem in the patients after major surgeries and is often difficult to diagnose because of nonspecific clinical symptoms. Diagnosis of pulmonary embolism is based on medical imaging methods. The aim of this study was to evaluate the results of CT pulmonary angiographies of the patients with primary clinical diagnosis of pul...

متن کامل

Development of a Simple and Sensitive Terbium Sensitized Fluorescence Method for Determination of Epinephrine and Norepinephrine in Serum

     A simple, rapid, selective and highly sensitive fluorimetric method for determination of two catecholamines, i.e. norepinephrine (NE) and epinephrine (EP), in serum samples was developed. The method is based on the fluorescence sensitization of terbium (Tb3+) by complexation with both catecholamines in the presence of lanthanum (La3+), as a co-cation, and in a Na...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 7  شماره 

صفحات  -

تاریخ انتشار 1961