The computer simulation of wear behavior appearing in total hip prosthesis

نویسندگان

  • James Shih-Shyn Wu
  • Jui-Pin Hung
  • Chi-Shiang Shu
  • Jian-Horng Chen
چکیده

Computer algorithms are proposed for the estimation of wear appearing in artificial hip joints using finite element analysis based on the modified Archard's wear law, contact features and an analogue wear process. A pin-on-disk plate experiment is reconstructed to assess the efficiency and validity of the algorithms proposed here. Through the successful verification of wear depth and volume loss of the pin-on-disk plate as well as the artificial hip joint, the current algorithms provide significant agreement with experiments, clinical measurements and numerical calculations and are shown to be both valid and feasible. Further investigation into the effect of femoral heads with various sizes suggests that the larger femoral head may induce larger wear volume but gives a smaller wear depth and that wear depth and volume loss are apparently nonlinearly related to the femoral head diameter. It is shown that the current algorithms are useful and helpful in understanding wear behavior for alternative or new designs of artificial hip joints and even for other analogous structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Wear Behavior of Biopolymers for Total Knee Replacements Through Invitro Experimentation

The average life span of knee prosthesis used in Total Knee Replacement (TKR) is approximately 10 to 15 years. Literature indicates that the reasons for implant failures include wear, infection, instability, and stiffness. However, the majority of failures are due to wear and tear of the prosthesis. The most common biopolymer used in TKR  is Ultra High Molecular Weight Polyethylene (UHMWPE). Pr...

متن کامل

Wear Testing of Total Hip Joints According to Iso and Development of a New Hip Joint Simulator According to Iso

INTRODUCTION The development of new, highly sophisticated materials for the articulating surfaces of total hip endoprostheses has led to an increasing demand for testing and verification. This includes tests and research regarding bio-compatibility, static load bearing capacity of the prostheses as well as tribological investigations. Since it has been found that wear debris play a dominant rol...

متن کامل

Wear comparison between a dual mobility total hip prosthesis and a typical modular design using a hip joint simulator

Rights: © 2010 Elsevier. This is the post print version of the following article: Saikko, Vesa & Shen, Ming. 2010. Wear comparison between a dual mobility total hip prosthesis and a typical modular design using a hip joint simulator. Wear. Volume 268, Issues 3-4. 617-621. ISSN 0043-1648 (printed). DOI: 10.1016/j.wear.2009.10.011, which has been published in final form at http://www.sciencedirec...

متن کامل

Generation of Fretting Wear Debris at the Stem– Cement Interface in Total Hip Replacment

Fretting wear debris generated at the stem–cement interface has nowadays been considered to play an important role in the overall failure of cemented total hip replacement (THR). Those wear debris within a certain size range would transport along bone cement deficiencies to bone tissue, resulting in a significant bone resorption and subsequent aseptic loosening of the femoral component, which i...

متن کامل

Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions

Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer methods and programs in biomedicine

دوره 70 1  شماره 

صفحات  -

تاریخ انتشار 2003