Integrated multimodal-catheter imaging unveils principal relationships among ventricular electrical activity, anatomy, and function.

نویسندگان

  • Liyun Rao
  • Yuesheng Ling
  • Renjie He
  • April L Gilbert
  • Nikolaos G Frangogiannis
  • Jianwen Wang
  • Sherif F Nagueh
  • Dirar S Khoury
چکیده

Multiple imaging modalities are employed independent of one another while managing complex cardiac arrhythmias. To combine electrical, anatomical, and functional imaging in a single catheter system, we developed a balloon catheter that carried 64 electrodes on its surface and an intracardiac echocardiography (ICE) catheter through a central lumen. The catheter system was inserted, and the balloon was inflated inside the left ventricle (LV) of eight dogs with 6-wk-old infarction, created by occlusion in the left anterior descending coronary artery. Anatomy was constructed by ICE imaging (9 MHz) through the balloon. Single-beat noncontact mapping (NCM) was performed via the multielectrode array to reconstruct unipolar endocardial electrograms during sinus rhythm. Standard contact mapping (CM) of the endocardium was also carried out for reference. Myocardial infarction in anterior LV extending from the middle to apical regions was localized both by ICE and NCM and validated by CM and pathology. The overall difference in the activation times between NCM and CM was 3 +/- 1 ms. Unipolar voltage in infarcted middle anterior LV was smaller than the voltage in normal middle inferior LV both by NCM (11 +/- 4 vs. 16 +/- 3 mV; P = 0.002) and CM (11 +/- 3 vs. 20 +/- 4 mV; P < 0.001). Unipolar voltage was also inversely related to infarct transmurality, both by NCM (r = -0.87; P = 0.005) and CM (r = -0.94; P < 0.001). The infarct area by ICE (7.7 +/- 2.9 cm(2)) was in agreement with CM (bipolar voltage, <1 mV; and area, 7.6 +/- 3.3 cm(2); r = 0.80; P = 0.016). Meanwhile, the voltage threshold that depicted the infarct area by NCM was directly related to the smallest unipolar voltage reconstructed within the infarct (r = 0.96; P < 0.001). In conclusion, combining NCM and ICE imaging in a single catheter system is feasible. The preclinical development of such an integrated system and its evaluation in experimental myocardial infarction demonstrate capabilities for single-beat mapping at multiple sites as well as the online assessment of anatomy and myocardial function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic resonance imaging to assess ventricular remodeling

Ventricular remodeling has a key role in the pathology of ventricular dysfunction. During the reaction to a myocardial insult, the ensuing genetic, structural, and biochemical changes will result in the deterioration of the functional ability of the heart in the long term. Non invasive imaging plays a central part in the diagnosis of heart failure, assessment of ventricular remodeling, prognosi...

متن کامل

Three-dimensional correction of conduction velocity in the embryonic heart using integrated optical mapping and optical coherence tomography.

Optical mapping (OM) of cardiac electrical activity conventionally collects information from a three-dimensional (3-D) surface as a two-dimensional (2-D) projection map. When applied to measurements of the embryonic heart, this method ignores the substantial and complex curvature of the heart surface, resulting in significant errors when calculating conduction velocity, an important electrophys...

متن کامل

The Future of Cardiac Mapping

Severe disorders of the heart rhythm that can lead to sudden cardiac death (SCD) are often treated by radio-frequency (RF) catheter ablation. Using fluoroscopy as an imaging guide, the procedure consists of inserting a catheter inside the heart, near the area from which originates the abnormal cardiac electrical activity, then delivering RF currents through the catheter tip to ablate the arrhyt...

متن کامل

A Method for Catheter Navigation within Realistic Three-Dimensional Cardiac Anatomy

We recently combined noncontact mapping and intracardiac echocardiography (ICE) in a single cathetersystem that permitted detailed, single-beat, 3-D electricalanatomical imaging of the heart. In the present study we developed a nonfluoroscopic electrode-catheter localization method and integrated it with noncontact electrical-anatomical imaging. The difference in nonfluoroscopic electrode locat...

متن کامل

Delivering Electrical Therapies for Heart Failure

Implantable devices have become a readily available option for patients with heart failure. Not only do these patients develop bradycardia and ventricular tachycardia, but their ventricular dysfunction can often improve with cardiac resynchronization therapy. However, this is a complex and rapidly developing clinical science for which the physician chooses techniques and selects patients on the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 294 2  شماره 

صفحات  -

تاریخ انتشار 2008