Body composition measures of obese adolescents by the deuterium oxide dilution method and by bioelectrical impedance.
نویسندگان
چکیده
The objectives of the present study were to describe and compare the body composition variables determined by bioelectrical impedance (BIA) and the deuterium dilution method (DDM), to identify possible correlations and agreement between the two methods, and to construct a linear regression model including anthropometric measures. Obese adolescents were evaluated by anthropometric measures, and body composition was assessed by BIA and DDM. Forty obese adolescents were included in the study. Comparison of the mean values for the following variables: fat body mass (FM; kg), fat-free mass (FFM; kg), and total body water (TBW; %) determined by DDM and by BIA revealed significant differences. BIA overestimated FFM and TBW and underestimated FM. When compared with data provided by DDM, the BIA data presented a significant correlation with FFM (r = 0.89; P < 0.001), FM (r = 0.93; P < 0.001) and TBW (r = 0.62; P < 0.001). The Bland-Altman plot showed no agreement for FFM, FM or TBW between data provided by BIA and DDM. The linear regression models proposed in our study with respect to FFM, FM, and TBW were well adjusted. FFM obtained by DDM = 0.842 x FFM obtained by BIA. FM obtained by DDM = 0.855 x FM obtained by BIA + 0.152 x weight (kg). TBW obtained by DDM = 0.813 x TBW obtained by BIA. The body composition results of obese adolescents determined by DDM can be predicted by using the measures provided by BIA through a regression equation.
منابع مشابه
Body Composition Estimatives by Anthropometry, Bioelectrical Impedance and Deuterium Oxide Dilution in Obese Adolescents
To evaluate the relationship between measures of body composition in obese adolescents by the methods of bioelectrical impedance analysis, deuterium oxide dilution and anthropometric measures, proposing an equation. The variables were weight, height, BMI, triceps and subscapular skinfold thickness, waist and arm muscle circumference, lean body mass, fat mass and total body water by bioelectrica...
متن کاملBioelectrical impedance with different equations versus deuterium oxide dilution method for the inference of body composition in healthy older persons.
BACKGROUND There is no consensus regarding the accuracy of bioimpedance for the determination of body composition in older persons. OBJECTIVE This study aimed to compare the assessment of lean body mass of healthy older volunteers obtained by the deuterium dilution method (reference) with those obtained by two frequently used bioelectrical impedance formulas and one formula specifically devel...
متن کاملVolaemic assessment of the elderly hyponatraemic patient: reliability of clinical assessment and validation of bioelectrical impedance analysis.
BACKGROUND Hyponatraemia is the commonest electrolyte disturbance of hospital inpatients. Assessment of volaemic status is an important part of diagnosis and management. AIM To determine reliability of clinical assessment of volaemic state by assessing inter-observer variability of clinical measures of volaemic state. To assess validity of bioelectrical impedance analysis as a tool to measure...
متن کاملBody composition measurement in obese patients with and without type 2 diabetes: comparison of methods
4 ACERO, Faculty of Health and Social Care School of Life Sciences, The Robert Gordon University, Aberdeen, Scotland, UK Background. Previous studies have compared body composition (BC) assessment methods in obese patients, however there is lack of literature on the comparison of bedside BC methods in obese diabetic subjects, particularly with respect to regional body fat (BF) distribution. The...
متن کاملA prediction equation for total body water from bioelectrical impedance in Japanese children.
Total body water (TBW) measured by isotope dilution techniques can be used to assess body composition safely and accurately in children. Unfortunately, this method is not readily available for most research projects, particularly when working with large groups of people, because the equipment is complicated and highly specialized. Bioelectrical impedance (BI) method is a simple, quick, and inex...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas
دوره 44 11 شماره
صفحات -
تاریخ انتشار 2011