Iterative deconvolution technique for measurements of diffraction-limited images on optical microscopes

نویسندگان

  • Wenlong Lu
  • Ming Chang
  • Po-Cheng Chen
  • Wun-Mao Luo
چکیده

Diffraction limit is usually a thorny problem in an optical inspection system. In this investigation, a model-based deconvolution technique was developed to recover diffraction-limited images, where images with sizes smaller than the diffraction limit could be recognized. Experiments were carried out with a traditional microscope at 200× magnification coupled with a halogen light source for a series of line width samples. The point spread function of the imaging optics was first obtained from an estimated model and then combined with a nonlinear deconvolution algorithm to calculate the full width at half maximum and reconstruct the line widths. Experimental results indicate that a measurement error below one pixel size of the measurement system is achievable. Accordingly, the target of nanoscale line width inspection based on a low cost and real-time image processing technique can be fulfilled, which greatly increases the ability of nanoscaling on optical microscopes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Principles and Applications of Difference Imaging

The principles of difference imaging outlined and the technique of Alard and Lupton (1997) is generalised to generate the best possible difference images to within the limits of measurement error. It is shown how for a large database of images we can approach diffraction-limited spatial resolution to within measurement error of a combined image. This is achieved through an iterative procedure o...

متن کامل

A New Image Restoration Technique for SEM

This paper proposes a new fast and effective method of image restoration to improve the resolution of SEM images. In our approach, image resolution is improved by deconvolution with the point spread function modeled as the intensity distribution of the electron beam at the specimen's surface. The beam intensity distribution under each imaging condition is estimated by electro-optical simulation...

متن کامل

Real-time restoration of white-light confocal microscope optical sections

Confocal microscopes (CM) are routinely used for building 3-D images of microscopic structures. Nonideal imaging conditions in a white-light CM introduce additive noise and blur. The optical section images need to be restored prior to quantitative analysis. We present an adaptive noise filtering technique using Karhunen-Loéve expansion (KLE) by the method of snapshots and a ringing metric to qu...

متن کامل

Doctor of Philosophy in Engineering

This thesis considers the problem of restoring an image distorted by a linear spatially invariant point spread function PSF and corrupted by noise A principle aim is to develop techniques that are practical and require a minimum amount of prior knowledge The process of deconvolution is attempted using least squares and maximum likelihood iterative algorithms A survey of the literature introduce...

متن کامل

Shape reconstruction techniques for optical sectioning of arbitrary objects

This paper considers the reconstruction of a shape from an object’s optical sectioning. To this end we describe three algorithms relying on the scalar optics model of light propagation of which the most involved is the deconvolution approach. This approach produces a sequence of deblurred images. We improve the deconvolution approach by suggesting a novel stopping criterion for the iterative pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 61  شماره 

صفحات  -

تاریخ انتشار 2014