Nitrous oxide as a tracer gas in the ASHRAE 110-1995 Standard.
نویسندگان
چکیده
ANSI/ASHRAE Standard 110 provides a quantitative method for testing the performance of laboratory fume hoods. Through release of a known quantity (4.0 Lpm) of a tracer gas, and subsequent monitoring of the tracer gas concentration in the "breathing zone" of a mannequin positioned in front of the hood, this method allows for evaluation of laboratory hood performance. Standard 110 specifies sulfur hexafluoride (SF6) as the tracer gas; however, suitable alternatives are allowed. Through three series of performance tests, this analysis serves to investigate the use of nitrous oxide (N2O) as an alternate tracer gas for hood performance testing. Single gas tests were performed according to ASHRAE Standard 110-1995 with each tracer gas individually. These tests showed identical results using an acceptance criterion of AU 0.1 with the sash half open, nominal 18 inches (0.46m) high, and the face velocity at a nominal 60 fpm (0.3 m/s). Most data collected in these single gas tests, for both tracer gases, were below the minimum detection limit, thus two dual gas tests were developed for simultaneous sampling of both tracer gases. Dual gas dual ejector tests were performed with both tracer gases released simultaneously through two ejectors, and the concentration measured with two detectors using a common sampling probe. Dual gas single ejector tests were performed with both tracer gases released though a single ejector, and the concentration measured in the same manner as the dual gas dual ejector tests. The dual gas dual ejector tests showed excellent correlation, with R typically greater than 0.9. Variance was observed in the resulting regression line for each hood, likely due to non-symmetry between the two challenges caused by variables beyond the control of the investigators. Dual gas single ejector tests resulted in exceptional correlation, with R>0.99 typically for the consolidated data, with a slope of 1.0. These data indicate equivalent results for ASHRAE 110 performance testing using either SF6 or N2O, indicating N2O as an applicable alternate tracer gas.
منابع مشابه
ارزیابی عملکرد هودهای آزمایشگاهی براساس استاندارد ASHRAE 110 در
Background and Aim: Laboratory fume-hoods are the first-level protection for the laboratory staff against hazardous chemical pollutants. Considering the large numbers of personnel, especially in petrochemical industry laboratories, this project was carried out in order to assess the performance of laboratory hoods based on tracer gas (SF6).Materials and Methods: In this project 22 hoods in the ...
متن کاملP110: Nitrous Oxide and Neuroinflammation
Nitrous oxide was an anaesthetic gas that was used for many years. There were many anaesthetic drugs in operations with many side effects. Nitrous oxide had some side effects too. But it was a safe gas in many times. In hospital personnel who worked in operating rooms exposure to this gas was important. The objective of this study was the introduction of nitrous oxide and neurologic side ...
متن کاملمروری بر خواص و عملکرد پیشرانه N2O در سیستمهای پیشرانش مختلف(علمی-ترویجی)
The purpose of this paper is to review the application and the status of mono propellant Nitrous oxide (N2O) as a high energetic material in the space industry. Therefore Nitrous oxide is introduced and its usage in propulsion systems is discussed. The results suggest that this compound lies in the development of the miniaturization concept of space propulsion systems. Because of this combinati...
متن کاملDFT Study of Nitrous Oxide Adsorption on the Surface of Pt-Decorated Graphene
In the present study we search potential of Pt-decorated graphene (PtG) as a new nanostructure adsorbent for nitrous oxide (N2O) using density functional theory (DFT). After fully relaxation of different possible orientations of N2O-PtG complex, we distinguished two optimized configurations for this system; 1- terminal N-side of gas is oriented towards Pt so that the molec...
متن کاملبررسی ارتباط غلظت گاز نیتروس اکساید بر مقدار کورتیزول ادرار در کارکنان اطاق های عمل
Aims and Background: The most common used anesthetic gas in operating rooms is nitrous oxide which is a poor anesthetic agent. Moreover, the level of serum cortisol is resumed as an indicator of stress. As a result an increase of serum cortisol could indicate stress and nervous condition. The aim of this study was to evaluate the relationship between the concentrations of anesthetic agen...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of occupational and environmental hygiene
دوره 11 1 شماره
صفحات -
تاریخ انتشار 2014