Transcutaneous Bilirubinometer

ثبت نشده
چکیده

Neonatal jaundice occurs in nearly 70% of term and 80% of preterm babies. Management of jaundiced neonates often requires measurement of total serum bilirubin (TSB). Total serum bilirubin (TSB) is commonly determined by spectro-photometric methods by analyzing plasma or serum sample. Such techniques require drawing of blood causing pain and trauma to the neonate. In addition, there is a wide range of intraand inter-laboratory variability in the performance of the bilirubin analyzers. These problems have led to search for a non-invasive, reliable technique for estimation of TSB. A large number of studies have demonstrated the possibility of prediction of serum bilirubin in neonates by measuring the yellowness of the skin in the jaundiced neonate using transcutaneous bilirubino-meters. Principle High correlation between cutaneous bilirubin and TSB form the basis of Transcutaneous Bilirubinometry. These meters work by directing light into the skin of the neonate and measuring the intensity of specific wavelength that is returned. The number of wavelengths, used is variable in different transcutaneous bilirubinometers. The meter analyzes the spectrum of optical signal reflected from the neonate’s subcutaneous tissues. These optical signals are converted to electrical signal by a photocell. These are analyzed by a microprocessor to generate a serum bilirubin value. The major skin components, which impart the spectral reflectance in neonate, are (i) melanin, (ii) dermal maturity, (iii) hemoglobin, and (iv) bilirubin. Earlier, the transcutaneous bilirubinometers utilized only a few wavelengths. In these meters, there was no provision to overcome the impact of dermal maturity and melanin content. Therefore, separate analysis for each patient population (different ages and races) was required one had to refer to different conversion tables for each population. However, a new product, Bilicheck (Specter, Inc) performs a spectral analysis at more than 100 different wavelengths. By subtracting the spectral contribution of the known components, the bilirubin absorbance is quantified. The available meters can be divided into 2 categories: (i) Multi wavelength Spectral Reflectance meters (Bilicheck) (ii) Two-wavelength (460 nm, 540 nm) Spectral Reflectance meters (Minolta, Bili-test)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of transcutaneous bilirubinometer estimates using BiliCheck in Thai neonates.

BACKGROUND Neonatal jaundice is the most frequently encountered diagnostic and therapeutic problem in the newborn. In the jaundiced infant, it is thought that the binding capacity of plasma albumin is exceeded, which allows free bilirubin to diffuse into and accumulate within extravascular tissues, such as the central nervous system. Affected newborns may develop kernicterus. The standard metho...

متن کامل

Transcutaneous bilirubinometry: an evaluation.

The transcutaneous bilirubinometer was evaluated in 60 term and 10 preterm infants. A significant correlation was found between the transcutaneous index and the total serum bilirubin concentration for both term and preterm infants. The reliability of the transcutaneous bilirubinometer as a screening method was confirmed, and index criteria for serum bilirubin analysis have been suggested for te...

متن کامل

Transcutaneous bilirubinometer in assessment of neonatal jaundice in northern India.

This study was undertaken from April 2002 to March 2003 to find out the correlation of transcutaneous bilirubinometer index with serum bilirubin levels in term, pre-term, small for gestation age babies, with and without phototherapy in neonates with jaundice. Another aim was to evaluate the transcutaneous bilirubinometer as a screening device for neonatal hyperbilirubinemia by finding the actio...

متن کامل

Comparison of transcutaneous and total serum bilirubin measurement in Turkish newborns.

Severe neonatal hyperbilirubinemia can be prevented by screening for neonatal jaundice. Transcutaneous bilirubin (TcB) measurement is a noninvasive method for screening neonates. The aim of this study was to examine the correlation between TcB measurement (using the JM-103 bilirubinometer) and total serum bilirubin (TSB) measurement. To our knowledge, this is the first study evaluating the usef...

متن کامل

مقایسه میانگین بیلی روبین اندازه گیری شده از طریق بیلی روبینومتر با میانگین بیلی روبین سرم در نوزادان زرد

Introduction: Hyperbilirubinemia is a common benign problem in neonates. Nonetheless, if untreated, severe hyperbilirubinemia is potentially neurotoxic. The standard method for diagnosis of hyperbilirubinemia is determination of serum bilirubin levels in the laboratory that requires a blood sample which is both painful and stressful for neonates and entails cost and time. The objective of thi...

متن کامل

Transcutaneous Bilirubin Nomogram for Healthy Term and Late Preterm Neonates in First 96 Hours of Life.

BACKGROUND To develop nomogram of Transcutaneous Bilirubin among healthy term and late-preterm neonates during first 96 hours of age. DESIGN Longitudinal observational study. SETTING Neonatal unit of a tertiary care Hospital of Central Gujarat, India. Participants 1075 healthy term and late preterm neonates (≥35weeks). INTERVENTION Six-hourly transcutaneous bilirubin was obtained from b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006