Photoacoustic Tomography Imaging of the Adult Zebrafish by Using Unfocused and Focused High-Frequency Ultrasound Transducers

نویسندگان

  • Yubin Liu
  • Dongliang Li
چکیده

The zebrafish model provides an essential platform for the study of human diseases or disorders due to the possession of about 87% homologous genes with human. However, it is still very challenging to noninvasively visualize the structure and function of adult zebrafish based on available optical imaging techniques. In this study, photoacoustic tomography (PAT) was utilized for high-resolution imaging of adult zebrafish by using focused and unfocused high-frequency (10 MHz) ultrasound transducers. We examined and compared the imaging results from the two categories of transducers with in vivo experimental tests, in which we discovered that the unfocused transducer is able to identify the inner organs of adult zebrafish with higher contrast but limited regional resolution, whereas the findings from the focused transducer were with high resolution but limited regional contrast for the recovered inner organs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Photoacoustic imaging in biomedicine

Photoacoustic imaging also called optoacoustic or thermoacoustic imaging has the potential to image animal or human organs, such as the breast and the brain, with simultaneous high contrast and high spatial resolution. This article provides an overview of the rapidly expanding field of photoacoustic imaging for biomedical applications. Imaging techniques, including depth profiling in layered me...

متن کامل

High Frequency Backscatter Measurements of Bovine Tissues with Unfocused and Focused Transducers

In order to improve resolution of ultrasonic imaging, high frequency scanners which are employed in the range 20 MHZ to 50 MHz are needed. As a result, it is critical to obtain data on ultrasonic scattering and attenuation in this frequency range. At these high frequencies, it is not feasible to make scattering measurements with unfocused transducers; therefore focused transducers are needed. U...

متن کامل

High-resolution photoacoustic imaging with focused laser and ultrasonic beams.

We report a photoacoustic imager that utilizes a focused laser beam in combination with a 20 MHz ultrasound focusing transducer to obtain micron-resolution tissue images over a long working distance. The imager is based on a ring transducer that combines ultrasonic and laser beams collinearly and confocally in a monolithic element. The combination of focused laser beam and short pulse irradiati...

متن کامل

Multiview Hilbert transformation for full-view photoacoustic computed tomography using a linear array.

Due to their low cost, hand-held convenience, wide selection of bandwidths, and ultrasound imaging capability, linear ultrasonic transducer arrays have been widely studied for photoacoustic computed tomography (PACT). As linear-array PACT suffers from a limited view, full-view imaging requires either the transducer or the object to be rotated. So far, both the central frequencies and bandwidth ...

متن کامل

Photoacoustic tomography of monkey brain using virtual point ultrasonic transducers.

A photoacoustic tomography system (PAT) using virtual point ultrasonic transducers was developed and applied to image a monkey brain. The custom-built transducers provide a 10-fold greater field-of-view (FOV) than finite-aperture unfocused transducers as well as an improved signal-to-noise ratio (SNR) and reduced artifacts rather than negative-lens transducers. Their tangential resolution, radi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016