High spatial resolution time-resolved magnetic resonance angiography of lower extremity tumors at 3T

نویسندگان

  • Gang Wu
  • Teng Jin
  • Ting Li
  • John Morelli
  • Xiaoming Li
چکیده

The aim of this study was to compare diagnostic value of high spatial resolution time-resolved magnetic resonance angiography with interleaved stochastic trajectory (TWIST) using Gadobutrol to Computed tomography angiography (CTA) for preoperative evaluation of lower extremity tumors.This prospective study was approved by the institutional review board. Fifty consecutive patients (31 men, 19 women, age range 18-80 years, average age 42.7 years) with lower extremity tumors underwent TWIST magnetic resonance angiography (MRA) and CTA. Digital subtraction angiography was available for 8 patients. Image quality of MRA was compared with CTA by 2 radiologists according to a 4-point Likert scale. Arterial involvement by tumor was compared using kappa test between MRA and CTA. The ability to identify feeding arteries and arterio-venous fistulae (AVF) was compared using Wilcoxon signed rank test and McNemar test, respectively.Image quality of MRA and CTA was rated without a statistically significant difference (3.88 ± 0.37 vs. 3.97 ± 0.16, P = 0.135). Intramodality agreement was high for the identification of arterial invasion (kappa = 0.806 ± 0.073 for Reader 1, kappa = 0.805 ± 0.073 for Reader 2). Readers found AVF in 27 of 50 MRA cases and 14 of 50 CTA cases (P < 0.001). Mean feeding arteries identified with MRA were significantly more than that with CTA (2.08 ± 1.72 vs. 1.62 ± 1.52, P = .02).TWIST MRA is a reliable imaging modality for the assessment of lower extremity tumors. TWIST MRA is comparable to CTA for the identification of AVF and feeding arteries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of High Spatial Resolution Time-Resolved 3D Con- trast-Enhanced MR Angiography

Introduction: Recently, computed tomographic angiography (CTA) has become widely used for lower extremity arterial runoff imaging, in part because of high spatial resolution and extended coverage obtained with continuous table movement during the exam. However, even with optimized technique, 2-3% of studies are nondiagnostic because of calcification, poor contrast opacification, or venous conta...

متن کامل

Intracranial time-resolved contrast-enhanced MR angiography at 3T.

BACKGROUND AND PURPOSE A method is presented for high-temporal-resolution MR angiography (MRA) using a combination of undersampling strategies and a high-field (3T) scanner. Currently, the evaluation of cerebrovascular disorders involving arteriovenous shunting or retrograde flow is accomplished with conventional radiographic digital subtraction angiography, because of its high spatial and temp...

متن کامل

Dedicated Calf MRA at 3T: Comparison of time-resolved MR Angiography with interleaved stochastic trajectories (TWIST) with standard high-resolution 3D contrast enhance MR Angiography (HR ceMRA)

¶ Figure 3: Calf station of left lower limb in patient with normal runoff arteries. (A) TWIST demonstrates focal occlusion of the distal anterior tibial artery (arrow) and a high grade stenosis of the distal posterior tibial artery (arrowhead) (B) HR ceMRA demonstrating normally appearing runoff arteries. Dedicated Calf MRA at 3T: Comparison of time-resolved MR Angiography with interleaved stoc...

متن کامل

Recent advances in 3D time-resolved contrast-enhanced MR angiography.

Contrast-enhanced magnetic resonance angiography (CE-MRA) was first introduced for clinical studies approximately 20 years ago. Early work provided 3-4 mm spatial resolution with acquisition times in the 30-second range. Since that time there has been continuing effort to provide improved spatial resolution with reduced acquisition time, allowing high resolution 3D time-resolved studies. The pu...

متن کامل

Assessment of craniospinal arteriovenous malformations at 3T with highly temporally and highly spatially resolved contrast-enhanced MR angiography.

BACKGROUND AND PURPOSE Patients with arteriovenous malformation (AVM) are known to have an elevated risk of complications with conventional catheter angiography (CCA) but nonetheless require monitoring of hemodynamics. Thus, we aimed to evaluate both anatomy and hemodynamics in patients with AVM noninvasively by using contrast-enhanced MR angiography (CE-MRA) at 3T and to compare the results wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 95  شماره 

صفحات  -

تاریخ انتشار 2016