Ozone disinfection: main parameters for process design in wastewater treatment and reuse

نویسندگان

  • Valentina Lazarova
  • Pierre-André Liechti
  • Philippe Savoye
  • Robert Hausler
چکیده

Wastewater disinfection by ozone was investigated at pilot and full scale on different wastewater effluents and two types of ozone reactors. It was demonstrated that water quality and, in particular, suspended solids and organic content strongly influence the required ozone dose for a given level of disinfection. The increase in contact time and residual ozone concentration did not improve the log removal of viruses and bacteria. However, the ‘Ct’ approach, commonly applied in drinking water treatment can be used for wastewater ozonation, if a sufficient ozone dose can be transferred to the effluent resulting in an ozone residual which can be measured. These considerations should be taken into account for the improved design of ozonation facilities. It should be underlined that short contact times are only possible if fast balanced distribution of the ozone dose is achieved as rapidly as possible, in order to satisfy fast chemical reactions (colloidal matter destabilisation, zeta potential, etc.) and enable a uniform distributed ozone residual for the slower reactions (disinfection, oxidation of micropollutants, etc.). doi: 10.2166/wrd.2013.007 Valentina Lazarova (corresponding author) Suez Environnement – CIRSEE, 38 rue du Président Wilson, 78230 le Pecq, France E-mail: [email protected] Pierre-André Liechti Ozone Knowhow, Gerenstrasse 73, CH-8105 Regensdorf, Switzerland Philippe Savoye Degrémont, 183 avenue du 18 juin 1940, 92508 Rueil Malmaison, France Robert Hausler ETS-UCAM, 1100, Notre-Dame Ouest, Montréal, Québec H3C 1K3, Canada

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

کارایی ازن زنی و اکسیداسیون پیشرفته (H2O2+O3) در حذف باکتری‌های کلیفرم از فاضلاب خام بیمارستان

Background and Objective: Hospital waste water due to infectious organisms and other risk factors is important. In this study, the possibility of coliform bacteria removal from hospital waste water using ozone separately and combining with hydrogen peroxide (H2O2 + O3) as a pre-treatment was investigated. Material and Methods: This is an experimental study that in the second moiety of 1392 i...

متن کامل

Pilot Plant Investigation of Ozone Disinfection of Physico- Chemically Treated Municipal Wastewater

An ozonation pilot plant was installed at the Montréal Urban Community Wastewater Treatment Plant (MUCWTP) to assess the feasibility of employing a full scale ozone disinfection system. Wastewater characteristics such as turbidity, COD, TOC, BOD, pH, ORP and suspended solids were monitored to assess their effect on ozone disinfection. Fecal conforms (FC) were used as indicators to measure disin...

متن کامل

Efficiency of Photocatalytic Ozone Process Combined with Zinc Oxide in Removal of Amoxicillin from Hospital Wastewater

Background and purpose: One of the main problems of pollution of aquatic environments is hardly biodegradable chemicals with high toxicity such as antibiotics. If they are not removed from the wastewater, particularly the hospital wastewater, many health and environmental hazards are created. Therefore, appropriate management and treatment of this type of wastewater is highly necessary. This re...

متن کامل

Destruction of Escherichia coli and Broad-Host-Range Plasmid DNA in Treated Wastewater by Dissolved Ozone Disinfection under Laboratory and Field Conditions

Broad-host-range plasmids are frequently associated with antibiotic resistance genes and can quickly spread antibiotic resistant phenotypes among diverse bacterial populations. Wastewater treatment plants have been identified as reservoirs for broad-host-range plasmids carrying resistance genes. The threat of broad-host-range plasmids released into the environment from wastewater treatment plan...

متن کامل

Ultraviolet Light

Ultraviolet light (UV) is a recognized disinfection alternative to chlorine and ozone in many applications from drinking water to wastewater treatment. UV provides effective disinfection without production of problematic disinfection byproducts. Information on the mechanism and application of UV for drinking water disinfection is presented. Advantages and disadvantages of the technique are disc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013