Stress and displacement patterns in the craniofacial skeleton with rapid maxillary expansion—a finite element method study

نویسندگان

  • J Priyadarshini
  • C M Mahesh
  • B S Chandrashekar
  • Abhishek Sundara
  • A V Arun
  • Vinay P Reddy
چکیده

BACKGROUND Rapid maxillary expansion (RME), indicated in the treatment of maxillary deficiency directs high forces to maxillary basal bone and to other adjacent skeletal bones. The aim of this study is to (i) evaluate stress distribution along craniofacial sutures and (ii) study the displacement of various craniofacial structures with rapid maxillary expansion therapy by using a Finite Element model. METHODS An analytical model was developed from a dried human skull of a 12 year old male. CT scan images of the skull were taken in axial direction parallel to the F-H plane at 1 mm interval, processed using Mimics software, required portion of the skull was exported into stereo-lithography model. ANSYS software was used to solve the mathematical equation. Contour plots of the displacement and stresses were obtained from the results of the analysis performed. RESULTS At Node 47005, maximum X-displacement was 5.073 mm corresponding to the incisal edge of the upper central incisor. At Node 3971, maximum negative Y-displacement was -0.86 mm which corresponds to the anterior zygomatic arch, indicating posterior movement of craniofacial complex. At Node 32324, maximum negative Z-displacement was -0.92 mm representing the anterior and deepest convex portion of the nasal septum; indicating downward displacement of structures medial to the area of force application. CONCLUSIONS Pyramidal displacement of maxilla was evident. Apex of pyramid faced the nasal bone and base was located on the oral side. Posterosuperior part of nasal cavity moved minimally in lateral direction and width of nasal cavity at the floor of the nose increased, there was downward and forward movement of maxilla with a tendency toward posterior rotation. Maximum von Mises stresses were found along midpalatal, pterygomaxillary, nasomaxillary and frontomaxillary sutures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical effects of rapid maxillary expansion on the craniofacial skeleton, studied by the finite element method.

The aim of this study was to evaluate the biomechanical effect of rapid maxillary expansion (RME) on the craniofacial complex by using a three-dimensional finite element model (FEM) of the craniofacial skeleton. The construction of the three-dimensional FEM was based on computer tomography (CT) scans of the skull of a 12-year-old male subject. The CT pictures were digitized and converted to the...

متن کامل

Comparison and evaluation of stresses generated by rapid maxillary expansion and the implant-supported rapid maxillary expansion on the craniofacial structures using finite element method of stress analysis

BACKGROUND The study aimed to evaluate and compare the stress distribution and 3-dimensional displacements along the craniofacial sutures in between the Rapid maxillary Expansion (RME) and Implant supported RME (I-RME). METHODS: Finite element model of the skull and the implants were created using ANSYS software. The finite element model thus built composed of 537692 elements and 115694 nodes ...

متن کامل

The effects of micro-implant assisted rapid palatal expansion (MARPE) on the nasomaxillary complex—a finite element method (FEM) analysis

BACKGROUND Orthodontic palatal expansion appliances have been widely used with satisfactory and, most often, predictable clinical results. Recently, clinicians have successfully utilized micro-implants with palatal expander designs to work as anchors to the palate to achieve more efficient skeletal expansion and to decrease undesired dental effects. The purpose of the study was to use finite el...

متن کامل

Stress distribution and displacement by different bone-borne palatal expanders with micro-implants: a three-dimensional finite-element analysis.

The aim of this study was to analyze stress distribution and displacement of the maxilla and teeth according to different designs of bone-borne palatal expanders using micro-implants. A three-dimensional (3D) finite-element (FE) model of the craniofacial bones and maxillary teeth was obtained. Four designs of rapid maxillary expanders: one with micro-implants placed lateral to mid-palatal sutur...

متن کامل

A comparison of three-dimensional stress distribution and displacement of naso-maxillary complex on application of forces using quad-helix and nickel titanium palatal expander 2 (NPE2): a FEM study

BACKGROUND Our objectives are to analyse and to compare the stress distribution and displacement of the craniofacial structures, following the application of forces from quad-helix and Nickel Titanium Palatal Expander-2 (NPE2) using finite element analysis. METHODS Three-dimensional finite element models of young dried human skull, quad-helix appliance and NPE2 were constructed, and the initi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017