Quantitative determination of chromophore concentrations from 2D photoacoustic images using a nonlinear model-based inversion scheme.
نویسندگان
چکیده
A model-based inversion scheme was used to determine absolute chromophore concentrations from multiwavelength photoacoustic images. The inversion scheme incorporated a forward model, which predicted 2D images of the initial pressure distribution as a function of the spatial distribution of the chromophore concentrations. It comprised a multiwavelength diffusion based model of the light transport, a model of acoustic propagation and detection, and an image reconstruction algorithm. The model was inverted by fitting its output to measured photoacoustic images to determine the chromophore concentrations. The scheme was validated using images acquired in a tissue phantom at wavelengths between 590 nm and 980 nm. The phantom comprised a scattering emulsion in which up to four tubes, filled with absorbing solutions of copper and nickel chloride at different concentration ratios, were submerged. Photoacoustic signals were detected along a line perpendicular to the tubes from which images of the initial pressure distribution were reconstructed. By varying the excitation wavelength, sets of multiwavelength photoacoustic images were obtained. The majority of the determined chromophore concentrations were within +/-15% of the true value, while the concentration ratios were determined with an average accuracy of -1.2%.
منابع مشابه
Forward and Adjoint Radiance Monte Carlo Models for Quantitative Photoacoustic Imaging
In quantitative photoacoustic imaging, the aim is to recover physiologically relevant tissue parameters such as chromophore concentrations or oxygen saturation. Obtaining accurate estimates is challenging due to the nonlinear relationship between the concentrations and the photoacoustic images. Nonlinear least squares inversions designed to tackle this problem require a model of light transport...
متن کاملA gradient-based method for quantitative photoacoustic tomography using the radiative transfer equation
Quantitative photoacoustic tomography (QPAT) offers the possibility of highresolution molecular imaging by quantifying molecular concentrations in biological tissue. QPAT comprises two inverse problems: (1) the construction of a photoacoustic image from surface measurements of photoacoustic wave pulses over time, and (2) the determination of the optical properties of the imaged region. The firs...
متن کاملQuantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration.
A new approach based on pulsed photoacoustic spectroscopy for non-invasively quantifying tissue chromophore concentrations with high spatial resolution has been developed. The technique is applicable to the quantification of tissue chromophores such as oxyhaemoglobin (HbO(2)) and deoxyhaemoglobin (HHb) for the measurement of physiological parameters such as blood oxygen saturation (SO(2)) and t...
متن کاملSensitivity of quantitative photoacoustic tomography inversion schemes to experimental uncertainty
The ability to accurately quantify chromophore concentration from photoacoustic images would have a major impact on pre-clinical and clinical imaging. Recent years have seen significant advances in the theoretical understanding of quantitative photoacoustic imaging and in the development of model-based inversion strategies that overcome issues such as non-uniqueness and non-linearity. Neverthel...
متن کاملQuantitative spectroscopic photoacoustic imaging: a review.
Obtaining absolute chromophore concentrations from photoacoustic images obtained at multiple wavelengths is a nontrivial aspect of photoacoustic imaging but is essential for accurate functional and molecular imaging. This topic, known as quantitative photoacoustic imaging, is reviewed here. The inverse problems involved are described, their nature (nonlinear and ill-posed) is discussed, propose...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 49 8 شماره
صفحات -
تاریخ انتشار 2010