Acute corneal epithelial change after instillation of benzalkonium chloride evaluated using a newly developed in vivo corneal transepithelial electric resistance measurement method.
نویسندگان
چکیده
OBJECTIVE Acute corneal permeability change after instillation of benzalkonium chloride (BAC) was evaluated using a newly developed in vivo corneal transepithelial electric resistance (TER) measurement method. METHOD Corneal TER was measured by Ag/AgCl electrodes placed in the anterior aqueous chamber and on the cornea of live rabbit eyes. TER was measured and TER change after instillation of 0.05% BAC solution was monitored. After TER measurement, cornea was excised and fixed for transmission and scanning electron microscopy. For the control study, physiologic saline was used instead of BAC. RESULTS The TER of normal rabbit cornea was 602.3 +/- 195.0 Omega cm(2). TER decreased instantly after instillation of 0.05% BAC. In 5 s, TER decreased to 58.3 +/- 5.2%. In 60 s, TER decreased to 18.5 +/- 3.2%. At all time points, TER after instillation of 0.05% BAC was significantly lower than that of the control (p < 0.0001). Dissociation of tight junctions and the destruction of superficial cell membranes were observed under electron microscopy. CONCLUSION Corneal epithelial change with increased permeability is rapid and intense after the instillation of highly concentrated BAC solution, accompanied by disorder of tight junctions and cell membranes of superficial cells. The newly developed in vivo corneal TER measurement method is suitable for assessing acute corneal change after drug instillation.
منابع مشابه
A novel in vivo corneal trans-epithelial electrical resistance measurement device.
PURPOSE To develop a device that is capable of easily measuring corneal transepithelial electrical resistance (TER) and changes in the corneal barrier function. METHODS We had previously developed an in vivo method for measuring corneal TER using intraocular electrode. This method can be used to precisely measure the decline of the corneal barrier function after instillation of benzalkonium c...
متن کاملInfluence of alkyl chain length of benzalkonium chloride on acute corneal epithelial toxicity.
PURPOSE To evaluate acute corneal epithelial toxicity induced by benzalkonium chloride (BAC) homologs with different alkyl chain lengths using an in vivo electrophysiological method. METHODS BAC homologs with C12, C14, and C16 alkyl chain lengths were used at concentrations of 0.0025%, 0.005%, and 0.01%, respectively. Cytotoxicity of BAC homologs on the normal rabbit corneal epithelial cells ...
متن کاملLocalization and Expression of Zonula Occludins-1 in the Rabbit Corneal Epithelium following Exposure to Benzalkonium Chloride
Preservatives are a major component of the ophthalmic preparations in multi-dose bottles. The purpose of this study was to investigate the acute effect of benzalkonium chloride (BAC), a common preservative used in ophthalmic preparations, on the localization and expression of zonula occludens (ZO)-1 in the rabbit corneal epithelium in vivo. BAC at 0.005%, 0.01%, or 0.02% was topically applied t...
متن کاملPolyoxyethylene hydrogenated castor oil modulates benzalkonium chloride toxicity: comparison of acute corneal barrier dysfunction induced by travoprost Z and travoprost.
PURPOSE To determine the element that modulates benzalkonium chloride (BAC) toxicity by using a new electrophysiological method to evaluate acute corneal barrier dysfunction induced by travoprost Z with sofZia (Travatan Z(®)), travoprost with 0.015% BAC (Travatan(®)), and its additives. METHODS Corneal transepithelial electrical resistance (TER) was measured in live white Japanese rabbits by ...
متن کاملInfluence of different additives and their concentrations on corneal toxicity and antimicrobial effect of benzalkonium chloride.
PURPOSE The aim of this study was to examine the ophthalmic additives responsible for modulating acute corneal epithelial toxicity induced by benzalkonium chloride (BAC) and investigate the ability of polyoxyethylene hydrogenated castor oil 40 (HCO-40) and polysorbate 80 (PS-80) to reduce the corneal toxicity and antimicrobial effects of BAC. METHODS Cytotoxicity of the additives, which inclu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Ophthalmic research
دوره 39 6 شماره
صفحات -
تاریخ انتشار 2007