Cone-Beam Iterative Reconstruction of a Segment of a Long Object
نویسندگان
چکیده
This study was performed to investigate the iterative reconstruction of a segment of a long object using cone-beam projections acquired with a practical-sized detector. This reconstruction problem is commonly called the cone-beam long object problem. The cone-beam focal-point trajectories studied were either helical or helical with planar arcs. We assume that the long object is confined in a tall supporting cylinder and that the cone-beam detector is wide enough that the projections are not truncated transversely. If the detector is not wide enough, we use two asymmetric cone-beam detectors, each covering at least one-half of the field of view in the transverse direction. The detector size in the axial direction is not large enough to cover the segment. The detector size is used to determine the maximal helical pitch. A data sufficiency condition is established to design a focal-point trajectory. The trajectory then defines a convex hull. Projection rays that touch the region outside the convex hull and inside the supporting cylinder are discarded in the iterative algorithm. Computer simulations and experimental data verify that the proposed data acquisition and discarding strategy result in accurate segment reconstruction.
منابع مشابه
Cone-Beam Iterative Recomtruction of a Segment of a Long Object
This study was performed to investigate the iterative reconstruction of a segment of a long object using cone-beam projections acquired with a practical-size detector. This reconstruction problem is commonly called the cone-beam long object problem. The cone-beam focal-point trajectories studied were either helical or helical with planar arcs. We assume that the long object is confined in a tal...
متن کاملArtifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملکاربرد تکنیک تصویربرداری Cone Beam Computed Tomography در تشخیص ودرمان سنترال ژانت سل گرانولوما تومور ؛ گزارش یک مورد
Introduction: Central giant cell granuloma (CGCG) is a relatively rare and non neoplastic tumor with unclear exact etiology that is reported in children. Cone beam computed tomography (CBCT) technique for precise diagnosis and treatment of the jaw lesions is recommended in the recent years. The object of this case-report study is to use CBCT in the diagnosis and treatment of CGCG. Case Repor...
متن کاملCone-Beam Composite-Circling Scan and Exact Image Reconstruction for a Quasi-Short Object
Here we propose a cone-beam composite-circling mode to solve the quasi-short object problem, which is to reconstruct a short portion of a long object from longitudinally truncated cone-beam data involving the short object. In contrast to the saddle curve cone-beam scanning, the proposed scanning mode requires that the X-ray focal spot undergoes a circular motion in a plane facing the short obje...
متن کامل3D Algebraic Iterative Reconstruction for Cone-Beam X-Ray Differential Phase-Contrast Computed Tomography
Due to the potential of compact imaging systems with magnified spatial resolution and contrast, cone-beam x-ray differential phase-contrast computed tomography (DPC-CT) has attracted significant interest. The current proposed FDK reconstruction algorithm with the Hilbert imaginary filter will induce severe cone-beam artifacts when the cone-beam angle becomes large. In this paper, we propose an ...
متن کامل