Treatment of edentulism using Astra Tech implants and ball abutments to retain mandibular overdentures.
نویسندگان
چکیده
The goal of this study was to provide evidence to support simplified treatment of mandibular edentulism using denture fabrication and implant placement to circumvent the need for second-stage surgeries or prosthodontic superstructures. A 5-year prospective clinical trial is reported, which involved treatment of mandibular edentulism using the single-stage surgical placement of a TiOblast microthreaded titanium screw implant with immediate replacement of a relieved mandibular overdenture and eventual retention of the overdenture with reduced ball abutments. Fifty-eight patients were treated; 116 implants were placed using a single-stage surgical approach, with a duplicate mandibular denture as the tomographic/surgical template. Mandibular dentures were relieved and relined with a tissue conditioning material and placed immediately after implant surgery. After 3 months, Conical Seal Design ball abutments were placed and attachments were secured in the overdentures by heat-polymerizing laboratory reline methods. Five of the 116 consecutively placed implants failed at 2 to 4 months, providing an immediate implant survival rate of 95.69% at the time of attachment connection. Pain and inflammation were not common to all failures, and infection was not reported in any of the 5 failures. The immediate placement of implants by a single-stage surgical procedure in the parasymphyseal region of the mandible, followed by placement of a relined mandibular denture, results in predictable and asymptomatic healing of implants that display the clinical and radiographic features of osseointegration. Encouraging results at the immediate observation period (attachment connection) must be tempered by the need for prudent and detailed clinical and radiologic evaluation over the 5-year trial period.
منابع مشابه
Overdentures supported by ASTRA TECH Implant SystemTM
Prospective clinical studies with the ASTRA TECH Implant System show that the survival rate of implants placed in the mandible is the same when comparing overdentures and fixed bridges, irrespective of retaining system used . The use of a ball abutment or a Locator for a non-splinted support, as well as the use of a bar attachment for a splinted support, is well documented with a followup of 1–...
متن کاملA Comparative Study of Three-implant Supported Fixed Dentures and Two-implant Retained Overdentures in Edentulous Mandible: Treatment Efficacy and Patient Satisfaction
KUANG-HAN CHANG: A Comparative Study of Three-implant Supported Fixed Dentures and Two-implant Retained Overdentures in Edentulous Mandible: Treatment Efficacy and Patient Satisfaction (Under the direction of Lyndon Cooper) The mandibular two-implant overdentures have been shown to be a highly successful treatment. However, for patients who desire a fixed prosthesis, overdentures may not satisf...
متن کاملComparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures
Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...
متن کاملComparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity
Comparison of stresses transferred to the implant supported overdentures with bar, ball and zaag attachments through photoelasticity Dr. A. Saboori* - Dr. Gh. Esfahanizade** - Dr. M. Ejlali*** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shaheed Beheshti University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Tehran Isl...
متن کاملImplant adaptation of stock abutments versus CAD/CAM abutments: a radiographic and Scanning Electron Microscopy study.
INTRODUCTION The study evaluated a null-hypothesis of no differences of fit between stock abutments and CAD/CAM titanium, gold sputtered and zirconia abutments when examined for radiographic adaptation and Scanning Electron Microcopy (SEM) at their inner aspect. The agreement between microscopic and radiographic fit was also assessed. METHODS Implants (Osseospeed, Astra Tech, Mölndal, Sweden)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 14 5 شماره
صفحات -
تاریخ انتشار 1999