The Stainless Steel Wire-based Method of Sogawa Effectively Corrects Severe Ingrown Nails

نویسندگان

  • Hitomi Sano
  • Koichiro Oki
  • Hideo Sogawa
  • Rei Ogawa
چکیده

Ingrown nails are defined as inflammation of the lateral nail fold that is caused by penetration by the nail plate and associates with pain and/or infection. The pain associated with ingrown nail hampers walking, raises the risk of falls, and decreases the quality of life. The Sogawa method is a novel conservative medical treatment for ingrown nails that is based on stainless steel wire. It was first reported in 2012 by Sogawa, and we have found that it is very effective for ingrown nails, especially in difficult cases. Here, we show the beneficial effects of the Sogawa method in 2 extremely difficult cases where ingrown nails had recurred after partial nail ablation. We found the Sogawa method to be a quick and easy technique that rapidly improves the pain associated with ingrown nails and later produces properly configured nails. Our experience suggests that it is suitable for severe ingrown nails, such as too short ingrown nails and ingrown nails that have strong inflammation and granulation tissue formation. This is significant because it is difficult to treat such cases with conventional conservative methods, which means that the only remaining therapeutic option is surgery. Thus, the Sogawa method is a novel and highly effective ingrown nail treatment that obviates the need for invasive surgical treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical comparison of stainless steel and titanium nails for fixation of simulated femoral fractures.

Flexible intramedullary nails are commonly used to treat femoral fractures in children. This study evaluated the biomechanical differences between stainless steel and titanium nails when securing transverse and comminuted fractures in a synthetic femur model. Retrograde flexible stainless steel and titanium nails placed in a divergent "C" pattern were mechanically tested, and axial rotation and...

متن کامل

Complications of titanium and stainless steel elastic nail fixation of pediatric femoral fractures.

BACKGROUND In vitro mechanical studies have demonstrated equal or superior fixation of pediatric femoral fractures with use of titanium elastic nails as compared with stainless steel elastic nails, and the biomechanical properties of titanium are often considered to be superior to those of stainless steel for intramedullary fracture fixation. We are not aware of any clinical studies in the lite...

متن کامل

Toxicity of used orthodontic archwires assessed by three-dimensional cell culture.

The aim of the present study was to determine whether used orthodontic wires made of different materials cause toxicity and loss of viability on three-dimensional (3D) cell cultures. Three types of orthodontic wires, stainless steel, Nitinol, and TMA (n = 9) which had been used clinically in fixed appliances for a period of 1 month, were retrieved at random from five patients. Both upper and lo...

متن کامل

Application of Polypyrrole Coated Stainless-Steel Wire to the Headspace Solid-Phase Microextraction of Aliphatic Amines

The electrochemical coating technique was used for the preparation of a polypyrrole coating on a stainless-steel wire, and applied as a fibre for solid phase microextraction (SPME). The polypyrrole fibre was employed for analyzing four volatile aliphatic amines (ethylamine, propylamine, butylamine and pentylamine) in water by headspace SPME using gas chromatography-flame ionization detection (G...

متن کامل

Microstructure of Horseshoe Nails Using Neutron Diffraction*

Neutron diffraction allows non-destructive testing of the bulk microstructure of mechanical components. The microstructures of horseshoe nails made through three different processes have been explored as a function of position along the nail. Despite all nails being made of similar plain low carbon steel and being process annealed after manufacture, the microstructures are far from the same. Na...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016