Design of a novel instrument for active neutron interrogation of artillery shells

نویسندگان

  • Camille Bélanger-Champagne
  • Hannes Vainionpää
  • Pauli Peura
  • Harri Toivonen
  • Paula Eerola
  • Peter Dendooven
چکیده

The most common explosives can be uniquely identified by measuring the elemental H/N ratio with a precision better than 10%. Monte Carlo simulations were used to design two variants of a new prompt gamma neutron activation instrument that can achieve this precision. The instrument features an intense pulsed neutron generator with precise timing. Measuring the hydrogen peak from the target explosive is especially challenging because the instrument itself contains hydrogen, which is needed for neutron moderation and shielding. By iterative design optimization, the fraction of the hydrogen peak counts coming from the explosive under interrogation increased from [Formula: see text]% to [Formula: see text]% (statistical only) for the benchmark design. In the optimized design variants, the hydrogen signal from a high-explosive shell can be measured to a statistics-only precision better than 1% in less than 30 minutes for an average neutron production yield of 109 n/s.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Neutron Dosimeter

Background: Neutron contamination in our environment can cause harmful biological effects on human body. Therefore, many efforts have been made to construct a neutron dosimeter to estimate the received dose. Objective: To design a simple neutron dosimeter. Methods: The primary dosimeter had 3He as a spherical thermal neutron detector encircled by paraffin 10 cm in radius. Then, the paraffin sph...

متن کامل

Optimizing neutron yield for active interrogation

Neutrons are commonly used for many applications, including active interrogation and cancer therapy. One critical aspect for active interrogation efficiency is neutron yield, which is more important for successful resolution than the energy spectrum. The typical approach for improving neutron yield entails producing more neutrons, which has motivated multiple studies using the interaction of in...

متن کامل

Passive neutron area monitor with CR39

Background: In high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with active detectors is useless in these conditions neutron measuring devices must have a passive detector. Here a passive neutron area monitor with CR39 track detector was designed and the response was calculated. Materials and Methods: The response of a passive neutron area monitor with C...

متن کامل

Development of Advanced Neutron/Gamma Generators for Imaging and Active Interrogation Applications

We report here on the development of neutron and photon sources for use in imaging and active interrogation applications, where there is a growing urgency for more advanced interrogation tools. These devices include high yield D-D, D-T and T-T fusion reaction based neutron generators and also low energy nuclear reaction based high-energy gamma generators. One common feature in these various dev...

متن کامل

Active Power Filter Design by a Novel Approach of Multi-Objective Optimization

This paper presents an innovative active power filter design method to simultaneously compensate the current harmonics and reactive power of a nonlinear load. The power filter integrates a passive power filter which is a RL low-pass filter placed in series with the load, and an active power filter which comprises an RL in series with an IGBT based voltage source converter. The filter is assumed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017