Bilateral outflow obstructions without ventricular septal defect in an adult: Illustrated by real-time 3D echocardiography.

نویسندگان

  • Jagdish C Mohan
  • Vishwas Mohan
چکیده

Double-chambered right ventricle with discrete subaortic stenosis without ventricular septal defect is rare in adults. This report shows incremental value of 3D echocardiography in delineating the pathoanatomy of these lesions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of 3D Echocardiography in Cardiac Surgery: Strengths and Limitations

PURPOSE OF REVIEW This review aims to highlight the general and specific strengths and limitations of intraoperative 3D echocardiography. This article explains the value of real-time three-dimensional transesophageal echocardiography (RT 3D TEE) during cardiac surgery and cardiac interventions. RECENT FINDINGS Recently published recommendations and guidelines include the use of RT 3D TEE. RT ...

متن کامل

Real-time 3-dimensional transesophageal echocardiography of the atrioventricular septal defect.

Being able to view the morphological details of the heart malformation in any patient with the diagnosis of atrioventricular septal defect (AVSD) is invaluable in surgical planning, especially in the current era of modified 1-patch versus 2-patch techniques. Real-time 3-dimensional transesophageal echocardiography (RT 3D TEE) is a recently developed technique that allows real-time high-quality ...

متن کامل

Posterior deviation of left ventricular outflow tract septal components without ventricular septal defect.

OBJECTIVE To describe 11 patients with narrowing of the left ventricular outflow tract caused by angular posterior deviation of both the outlet septum and the upper part of trabecular septum, which was diagnosed by cross sectional echocardiography in all and confirmed by angiocardiography in seven. RESULTS Four patients had a subaortic systolic pressure gradient ranging from 23 to 70 mm Hg by...

متن کامل

Percutaneous closure of a post-myocardial infarction ventricular septal defect guided by real-time three-dimensional echocardiography.

We present an adult patient who had an acute myocardial infarction complicated by a ventricular septal defect and had it repaired percutaneously. Real-time three-dimensional echocardiography (RT3D) before and during the closure procedure were performed. RT3D provided anatomical and functional information of the defect as well as real-time guidance during the procedure. This case highlights the ...

متن کامل

Intraoperative three-dimensional transesophageal echocardiography for evaluating an unusual structure in the left ventricular outflow tract: a case report

Intraoperative three-dimensional (3D) transesophageal echocardiography (TEE) facilitates an understanding of the complex cardiac pathology that is not fully delineated in a two-dimensional (2D) echocardiographic evaluation, and it suggests earlier and more precise surgical planning and intraoperative decision making. In the present case, the intraoperative 2D-TEE midesophageal long-axis view in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indian heart journal

دوره 67 4  شماره 

صفحات  -

تاریخ انتشار 2015