An objective analysis of the pressure-volume curve in the acute respiratory distress syndrome.

نویسندگان

  • R S Harris
  • D R Hess
  • J G Venegas
چکیده

To assess the interobserver and intraobserver variability in the clinical evaluation of the quasi-static pressure-volume (P-V) curve, we analyzed 24 sets of inflation and deflation P-V curves obtained from patients with ARDS. We used a recently described sigmoidal equation to curve-fit the P-V data sets and objectively define the point of maximum compliance increase of the inflation limb (P(mci, i)) and the true inflection point of the deflation limb (P(inf,d)). These points were compared with graphic determinations of lower Pflex by seven clinicians. The graphic and curve-fitting methods were also compared for their ability to reproduce the same parameter value in data sets with reduced number of data points. The sigmoidal equation fit the P-V data with great accuracy (R(2) = 0.9992). The average of Pflex determinations was found to be correlated with P(mci,i) (R = 0.89) and P(inf,d) (R = 0.76). Individual determinations of Pflex were less correlated with the corresponding objective parameters (R = 0.67 and 0.62, respectively). Pflex + 2 cm H(2)O was a more accurate estimator of P(inf,d) (2 SD = +/-6.05 cm H(2)O) than Pflex was of P(mci,i) (2 SD = +/-8.02 cm H(2)O). There was significant interobserver variability in Pflex, with a maximum difference of 11 cm H(2)O for the same patient (SD = 1.9 cm H(2)O). Clinicians had difficulty reproducing Pflex in smaller data sets with differences as great as 17 cm H(2)O (SD = 2.8 cm H(2)O). In contrast, the curve-fitting method reproduced P(mci,i) with great accuracy in reduced data sets (maximum difference of 1.5 cm H(2)O and SD = 0.3 cm H(2)O). We conclude that Pflex rarely coincided with the point of maximum compliance increase defined by a sigmoid curve-fit with large differences in Pflex seen both among and within observers. Calculating objective parameters such as P(mci,i) or P(inf,d) from curve-fitted P-V data can minimize this large variability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute Respiratory Distress Syndrome in a Patient With Suspected Influenza: A Case Report

Acute Respiratory Distress Syndrome (ARDS) is a clinical syndrome consisting of tachypnea, refractory hypoxemia, and diffuse opacities on chest radiographs after infection or trauma which ultimately leads to respiratory failure. The principles of treatment are based on patient care in ICU, mechanical ventilation and medical treatments. By using lower plateau, less tidal volume, higher positive ...

متن کامل

Rhabdomyolysis and Acute Respiratory Distress Syndrome Secondary to Multiple Wasp Stings

Background: Wasp stings usually cause local reactions such as itching, urticaria, angioedema and anaphylaxis. Life-threatening complications following multiple wasp stings are relatively rare and unexpected. However, rhabdomyolysis and acute respiratory distress syndrome following wasp stings are possible. Case presentation: A middle-aged male worker was stung by a swarm of wasps all over his b...

متن کامل

Predictive Factors of Acute Renal Failure in the Neonates with Respiratory Distress Syndrome

Background: Preterm birth occurs in a large number of pregnancies, and its incidence has been reported to be on the rise. Acute kidney injury (AKI) is a common complication in the premature infants with respiratory distress syndrome (RDS). The present study aimed to determine the predictive factors, clinical courses, and outcomes of AKI in the neonates with the clinical and radiological manifes...

متن کامل

Utilization of the Lower Inflection Point of the Pressure-Volume Curve Results In Protective Conventional Ventilation Comparable to High Frequency Oscillatory Ventilation in an Animal Model of Acute Respiratory Distress Syndrome

INTRODUCTION Studies comparing high frequency oscillatory and conventional ventilation in acute respiratory distress syndrome have used low values of positive end-expiratory pressure and identified a need for better recruitment and pulmonary stability with high frequency. OBJECTIVE To compare conventional and high frequency ventilation using the lower inflection point of the pressure-volume c...

متن کامل

Volume-guaranteed Ventilation Versus Pressure-controlled Ventilation in Preterm Infants with Respiratory Distress Syndrome: A Randomized Controlled Trial

Background: This study was targeted toward comparing volume-guaranteed (VG) ventilation with conventional pressure-controlled (PC) ventilation in preterm infants with respiratory distress syndrome (RDS) in terms of the facilitation of weaning and extubation and occurrence of complications, such as pneumothorax, intraventricular hemorrhage (IVH), retinopathy of prematur...

متن کامل

Lung protection strategy as an effective treatment in acute respiratory distress syndrome

Lung protection strategy as an effective treatment in acute respiratory distress syndrome

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of respiratory and critical care medicine

دوره 161 2 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2000