Computerized tomographic angiography in patients having eSVS Mesh® supported coronary saphenous vein grafts: intermediate term results

نویسندگان

  • Uwe Klima
  • Abdalla A Elsebaey
  • Mohamed R Gantri
  • Jochen Bongardt
  • Gary Miller
  • Robert W Emery
چکیده

BACKGROUND The Saphenous Vein (SVG) is used in over 80% of coronary artery bypass procedures (CABG) and SVG patency is the Achilles heel of CABG. To address this issue, the eSVS Mesh(R), an external Nitinol knitted mesh, fitted like a sleeve over the vein graft preventing over expansion in the high pressure arterial system, has been introduced to improve disease management. Patency data is limited. The objective of this retrospective study is to report patency rates (>3 months) in patients having external mesh support as part of CABG. METHODS From October 25, 2010 through February 13, 2012, 21 patients had external mesh support of SVG grafts in addition to internal thoracic artery grafting to the Anterior Descending artery. Patients were invited to return for patency evaluation using Computerized Tomographic angiography (CTA) an average of 7.2 months post-operative (R = 3-14 months). RESULTS 21 male patients (age 57+/- 9 years) underwent on-pump surgery. The eSVS Mesh was successfully placed on all SVGs. All grafts were determined patent intra-operative by transit time Doppler measurement and there were no operative revisions. There was no operative mortality. 12 of the 21 contacted patients returned for CTA, 8 non-returning patients contacted were alive and asymptomatic but refused to return due to travel restrictions or cost. One patient was lost to follow up. 11 returning patients underwent CTA. One patient was excluded (asymptomatic) due to elevated creatinine. Of the 23 anastomoses in 11 patients(Average: 2.09 grafts/patient) using SVG available for examination, 21 were patent (92%). CONCLUSIONS In this retrospective non-randomized experience, the external mesh supported grafts displayed excellent intermediate patency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

One-year patency control and risk analysis of eSVS®-mesh-supported coronary saphenous vein grafts

BACKGROUND The eSVS® external venous nitinol mesh (Kips Bay Medical, Minneapolis, USA) was designed to improve long-term patency of coronary saphenous vein grafts (SVG) by preventing pressure-induced wall stress and reactive neo-intimal hyperplasia. We present one-year-patency rates of meshed SVGs assessed by coronary computed tomographic angiography (cCTA). PATIENTS AND METHODS Data from con...

متن کامل

Radial artery versus saphenous vein patency randomized trial: five-year angiographic follow-up.

BACKGROUND Graft patency is a fundamental predictor of long-term survival after coronary artery bypass surgery. Left and right internal thoracic artery (arterial) graft patency has been shown to be superior to that of saphenous vein grafts. More recently, the radial artery has been used as an aortocoronary graft, but little is known about the midterm and long-term patency of this conduit. We pe...

متن کامل

External stenting of saphenous vein bypass grafts does not affect intraoperative transit-time flow measurement.

Results There was no significant difference between two groups regarding pre and peri-operative parameters, although more patients in the eSVS mesh group had concomitant procedures (3, 23% vs. 2, 15%, P > 0.99). All SVG were patent in both groups at the end of the surgical procedure and TTFM values were similar. eSVS mesh group had a trend for longer cardiopulmonary and aortic cross clamping ti...

متن کامل

Routine intraoperative angiography improves the early patency of coronary grafts performed on the beating heart.

OBJECTIVES The techniques of performing coronary revascularization without cardiopulmonary bypass are rapidly evolving. However, concern remains regarding the accuracy of coronary artery anastomoses performed on the beating heart. This report reviews the use of intraoperative angiography in the critical appraisal of "off-pump" coronary artery bypass graft (CABG) surgery. PATIENTS Intraoperati...

متن کامل

Major Leg Wound Complications After Saphenous Vein Harvest for Coronary Revascularization

Background: Major leg wound complications after coronary artery bypass graft procedures are infrequent and few are reported in the litrature.We present our experience in treating 30 patients with major leg wound complications after coronary revascularization procedures. Materials and Methods: A retrospective review of 2100 bypass procedures with saphenous veingraft performed over a 5-years p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014