The Mini-Balance Evaluation Systems Test (Mini-BESTest) Demonstrates Higher Accuracy in Identifying Older Adult Participants With History of Falls Than Do the BESTest, Berg Balance Scale, or Timed Up and Go Test.

نویسندگان

  • Anyamanee Yingyongyudha
  • Vitoon Saengsirisuwan
  • Wanvisa Panichaporn
  • Rumpa Boonsinsukh
چکیده

BACKGROUND AND PURPOSE Balance deficits a significant predictor of falls in older adults. The Balance Evaluation Systems Test (BESTest) and the Mini-Balance Evaluation Systems Test (Mini-BESTest) are tools that may predict the likelihood of a fall, but their capabilities and accuracies have not been adequately addressed. Therefore, this study aimed at examining the capabilities of the BESTest and Mini-BESTest for identifying older adult with history of falls and comparing the participants with history of falls identification accuracy of the BESTest, Mini-BESTest, Berg Balance Scale (BBS), and the Timed Up and Go Test (TUG) for identifying participants with a history of falls. METHODS Two hundred healthy older adults with a mean age of 70 years were classified into participants with and without history of fall groups on the basis of their 12-month fall history. Their balance abilities were assessed using the BESTest, Mini-BESTest, BBS, and TUG. An analysis of the resulting receiver operating characteristic curves was performed to calculate the area under the curve (AUC), sensitivity, specificity, cutoff score, and posttest accuracy of each. RESULTS The Mini-BESTest showed the highest AUC (0.84) compared with the BESTest (0.74), BBS (0.69), and TUG (0.35), suggesting that the Mini-BESTest had the highest accuracy in identifying older adult with history of falls. At the cutoff score of 16 (out of 28), the Mini-BESTest demonstrated a posttest accuracy of 85% with a sensitivity of 85% and specificity of 75%. The Mini-BESTest had the highest posttest accuracy, with the others having results of 76% (BESTest), 60% (BBS), and 65% (TUG). CONCLUSION The Mini-BESTest is the most accurate tool for identifying older adult with history of falls compared with the BESTest, BBS, and TUG.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative utility of the BESTest, mini-BESTest, and brief-BESTest for predicting falls in individuals with Parkinson disease: a cohort study.

BACKGROUND The newly developed brief-balance evaluation system test (brief-BESTest) may be useful for measuring balance and predicting falls in individuals with Parkinson disease (PD). OBJECTIVES The purposes of this study were: (1) to describe the balance performance of those with PD using the brief-BESTest, (2) to determine the relationships among the scores derived from the 3 versions of t...

متن کامل

Is the BESTest at its best? A suggested brief version based on interrater reliability, validity, internal consistency, and theoretical construct.

BACKGROUND The Balance Evaluation Systems Test (BESTest) and Mini-BESTest are clinical examinations of balance impairment, but the tests are lengthy and the Mini-BESTest is theoretically inconsistent with the BESTest. OBJECTIVE The purpose of this study was to generate an alternative version of the BESTest that is valid, reliable, time efficient, and founded upon the same theoretical underpin...

متن کامل

Comparison of the Fullerton Advanced Balance Scale, Mini-BESTest, and Berg Balance Scale to Predict Falls in Parkinson Disease.

BACKGROUND The correct identification of patients with Parkinson disease (PD) at risk for falling is important to initiate appropriate treatment early. OBJECTIVE This study compared the Fullerton Advanced Balance (FAB) scale with the Mini-Balance Evaluation Systems Test (Mini-BESTest) and Berg Balance Scale (BBS) to identify individuals with PD at risk for falls and to analyze which of the it...

متن کامل

The mini-BESTest can predict parkinsonian recurrent fallers: a 6-month prospective study.

OBJECTIVES To examine whether the Mini-Balance Evaluation Systems Test (Mini-BESTest) independently predicts recurrent falls in people with Parkinson's disease. DESIGN The study used a longitudinal cohort design. SUBJECTS A total of 110 patients with Parkinson's disease completed the study and were included in the final analysis. Most of the patients had moderate disease severity. METHODS...

متن کامل

Accuracy of Fall Prediction in Parkinson Disease: Six-Month and 12-Month Prospective Analyses

Introduction. We analyzed the ability of four balance assessments to predict falls in people with Parkinson Disease (PD) prospectively over six and 12 months. Materials and Methods. The BESTest, Mini-BESTest, Functional Gait Assessment (FGA), and Berg Balance Scale (BBS) were administered to 80 participants with idiopathic PD at baseline. Falls were then tracked for 12 months. Ability of each t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of geriatric physical therapy

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 2016