Humeral Fracture Fixation Techniques: a Fea Comparison of Locking and Compression Techniques with Cadaveric Pullout Comparison of Cortical Compression and Internal Locking Screws
نویسندگان
چکیده
Title of Document: HUMERAL FRACTURE FIXATION TECHNIQUES: A FEA COMPARISON OF LOCKING AND COMPRESSION TECHNIQUES WITH CADAVERIC PULLOUT COMPARISON OF CORTICAL COMPRESSION AND INTERNAL LOCKING SCREWS. Aaron Johnson, MS Mechanical Engineering, 2007 Directed By: Professor, Donald Barker, Mechanical Engineering Locking and non-locking humeral repair techniques provide different mechanical constructs for securing fractures, and consequently could generate different strain fields at the callus. The purpose of this study was to investigate the strain field callus, and to compare to determine if one construct offers a healing advantage over another. An FEA analysis was conducted using ABAQUS, with all contact surfaces modeled as friction interfaces; additionally, a pretension was applied to the non-locking construct to simulate the effect of installation. The models were subjected to axial tension loads, and results were compared with existing cadaveric and synthetic experimental loading. Additional validation involved screw pullout testing conducted on cadaveric humeri. Results showed that the strain fields at the fracture site showed no significant variation in distribution, shape, or magnitude, therefore concluding that the locking plate offered no biomechanical healing advantage. HUMERAL FRACTURE FIXATION TECHNIQUES: A FEA COMPARISON OF LOCKING AND COMPRESSION TECHNIQUES WITH CADAVERIC PULLOUT COMPARISON OF CORTICAL COMPRESSION AND INTERNAL LOCKING SCREWS.
منابع مشابه
A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملLocked plate fixation of osteoporotic humeral shaft fractures: are two locking screws per segment enough?
OBJECTIVE The purpose of this study was to compare the biomechanical behavior of using two versus three locking screws per bone segment in a cadaveric humerus fracture gap model. METHODS Six matched pairs of elderly osteoporotic fresh-frozen human cadaveric humerii were used. An eight-hole locking compression plate was placed posteriorly on the humeral shaft and secured with either four or si...
متن کاملFirst Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملDanger zone for locking screw placement in minimally invasive plate osteosynthesis (MIPO) of humeral shaft fractures: a cadaveric study.
Several recent reports have described the minimally invasive plate osteosynthesis (MIPO) technique in the treatment of humeral shaft fractures by the anterior approach. The purpose of this study is to identify the danger zone for locking screw placement to avoid musculocutaneous nerve injury in the anterior compartment and radial nerve injury in the posterior compartment of the humerus relative...
متن کاملFirst Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw
Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007