An evaluation of the Hitachi 705 analyser
نویسندگان
چکیده
منابع مشابه
Evaluation of a new inhibitor test for isoamylase on Hitachi 705 analyser.
We describe a simple and rapid method for measuring pancreatic and salivary type amylases using the Hitachi 705 analyser. The determination is based on the inhibition of salivary amylase using an inhibitor isolated from wheat germ. The precision of the proposed method was very good: within-day precision varied from 0.4 to 2.5% (CV) and day-to-day precision from 2.2 to 3.7% (CV). The new applica...
متن کاملA continuous method for the estimation of adenosine deaminase catalytic concentration in pleural effusions with a Hitachi 705 discrete analyser.
An assay of adenosine deaminase activity in pleural effusions is described. For the continuous determination of adenosine deaminase, the liberated ammonia is estimated by coupling the liberated NH3 with 2-oxoglutarate. The reaction is followed by the decrease of NADH absorbance at 340 nm. The assay was optimized for a Hitachi 705 analyser, with respect to pH, adenosine concentration and glutama...
متن کاملLaboratory evaluation of the COBAS MIRA S random access analyser
The random access analyser COBAS MIRA S (Roche Diagnostics) was evaluated for two months. The instrument is a computer-controlled discrete analyser which can be run in a combination profile and single test mode. This instrument has special features, including an automatic cuvette segment changer, a reagent rack cooling system, an external keyboard and monitor, as well as a bar-code facility for...
متن کاملQuality assessment of the Reflotron System. A blood chemistry reagent strip analyser.
We tested the accuracy of the Reflotron System by comparing results given by this system for estimations of glucose, SGOT, SGPT, cholesterol and triglycerides on patients samples which were already analysed on either an autoanalyser HITACHI 705 or manually on CLIN ICON 4010. Reflotron estimations correlated well with both Hitachi and Clinicon estimations and the strips gave reproducible results...
متن کاملEvaluation of a random access analyser: BM/Hitachi 911
The performance of Boehringer Mannheim's BM/Hitachi 911 was evaluated for three months. The mean coeffcient of variation (CV) of the within-run and between-run imprecision of the 16 analytes were less than 1.16% (range 0.47-2.38%) and 1.35% (range 0.62-2.93,%), respectively. A linearity study for the various assays covered clinically important levels. No relevant drift was observed during an ei...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 6 شماره
صفحات -
تاریخ انتشار 1984