Measurement of joint effusion and haematoma formation by ultrasound in assessing the effectiveness of drains after total knee replacement: A prospective randomised study.
نویسندگان
چکیده
We prospectively randomised 78 patients into two groups, 'drains' or 'no drains' to assess the effectiveness of suction drains in reducing haematoma and effusion in the joint and its effect on wound healing after total knee replacement. Ultrasound was used to measure the formation of haematoma and effusion on the fourth post-operative day. This was a semi-quantitative assessment of volume estimation. There was no difference in the mean effusion between the groups (5.91 mm in the drain group versus 6.08 mm in the no-drain, p = 0.82). The mean amount of haematoma in the no-drain group was greater (11.07 mm versus 8.41 mm, p = 0.03). However, this was not clinically significant judged by the lack of difference in the mean reduction in the post-operative haemoglobin between the groups (drain group 3.4 g/dl; no-drain group 3.0 g/dl, p = 0.38). There were no cases of wound infection or problems with wound healing at six weeks in any patient. Our findings indicate that drains do not reduce joint effusion but do reduce haematoma formation. They have no effect on wound healing.
منابع مشابه
A prospective randomised controlled trial of autologous retransfusion in total knee replacement.
We undertook a prospective randomised controlled trial to investigate the efficacy of autologous retransfusion drains in reducing the need for allogenic blood requirement after unilateral total knee replacement. We also monitored the incidence of post-operative complications. There were 86 patients in the control group, receiving standard care with a vacuum drain, and 92 who received an autolog...
متن کاملA comparison of ultrasound guided corticosteroid injection vs ozone injection in grade 3 knee osteoarthritis
Background: Osteoarthritis (OA) is a degenerative disease that can cause pain and limited function. One of the non-surgical treatments is intra-articular ozone injection. This study aimed to compare the effect of ultrasound-guided corticosteroid injection with ozone injection in patients with grade 3 osteoarthritis of the knee. Methods: This randomized, double-blind, clinical trial was carried...
متن کاملThe effect of suction drains after total hip replacement.
A prospective study of 120 consecutive total hip replacements showed that deep suction drains produced maximal drainage volumes in the first 24 hours. Their continued presence resulted in minimal further drainage, did not reduce the likelihood of haematoma formation and led in some cases to the spread of skin organisms into the wound.
متن کاملTOTAL KNEE REPLACEMENT IN VARUS KNEE: WHAT MEASUREMENT REALLY MATTERS? INTRODUCING A NEW CLASSIFICATION SYSTEM
This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran
متن کاملتأثیر ویبریشن موضعی روی عضله چهار سررانی بر درمان عوارض استئوآرتریت زانو
S. Mohammadi [1] , A.H. Bakhtiary [2] , H. Tabesh [3] , J. Moghimi [4] , R. Ghorbani [5] Received: 09/01/2012 Sent for Revision: 09/04/2012 Received Revised Manuscript: 07/08/2012 Accepted: 08/08/2012 Background and Objectives: Recently, vibration has been used widely as a rehabilitation intervention for neuro-musculo-skeletal disorders. As, the knee osteoarthritis (OA) is a common j...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 92 1 شماره
صفحات -
تاریخ انتشار 2010