Tremor mimicking ventricular tachycardia.
نویسندگان
چکیده
E326 CMAJ, July 14, 2015, 187(10) ©2015 8872147 Canada Inc. or its licensors A 92-year-old woman was admitted to hospital with pneumonia. Her medical history included a percutaneous coronary intervention and subsequent diagnosis of ischemic cardiomyopathy 15 years earlier. While in hospital, epigastric and retrosternal pain associated with nausea developed in the patient. On physical examination, she was anxious and tremulous. Her blood pressure was 145/85 mm Hg, her pulse was regular at 75 beats/min, and she was afebrile. On cardiac auscultation, she had normal first and second heart sounds, a regular rhythm of 75 beats/min and no audible murmur. At first glance, simultaneous bedside analysis of an electrocardiographic (ECG) tracing suggested the presence of a broad QRS complex tachycardia (Figure 1). Because the patient was anxious, the on-call doctor held her left hand during the test. As a consequence, the patient’s left hand was not shaking during the ECG tracing, unlike the right hand. Because lead III showed a normal sinus rhythm and the observed clinical picture did not suggest ventricular tachycardia, a diagnosis of tremor-induced artifact was proposed. Tremor can cause ECG artifacts that mimic a broad QRS complex tachycardia.1 Characteristics allowing differentiation from a broad QRS complex tachycardia include the finding of normal QRS complexes between artifact waves (Figure 1, small arrows) or an unstable baseline at the beginning of the ECG recording (not shown). One of the upper extremities is often free of tremor, which results in a normal ECG tracing in one of the frontal leads (Figure 1, large arrow).2 A simple bedside evaluation allows for the recognition of important clinical clues, such as a tremulous patient without hemodynamic compromise and detection of a normal pulse during palpitation or cardiac auscultation. Misdiagnosing artifacts as ventricular tachycardia may result in patients having to undergo a range of unnecessary diagnostic and therapeutic procedures, including electrophysiologic testing, antiarrhythmic drugs, cardiac catheterization and even placement of an implantable cardioverter defibrillator.3
منابع مشابه
Parkinson's tremor mimicking ventricular tachycardia.
We report the case of an elderly lady with Parkinson's tremor whose electrocardiographic (ECG) appearance simulated ventricular tachycardia. As a result she underwent unnecessary clinical intervention. We also highlight the difficulty in correctly identifying a tremor-induced ECG artefact with regard to Parkinson's disease, due to the diverse range of possible clinical scenarios presented by pa...
متن کاملTremor-induced ECG artifact mimicking ventricular tachycardia.
Ventricular Tachycardia To the Editor: The ECG from the article by Srikureja et al1 that adorns the cover of the September 12, 2000, issue of Circulation is a striking example of a tremor-induced artifact mimicking a serious arrhythmia. On this occasion, the apparent arrhythmia was ventricular tachycardia and led to the patient’s admission to the coronary care unit, although, in my experience, ...
متن کاملTeaching neuroImages: Rest tremor mimicking ventricular tachycardia.
Ventricular tachycardia is a life-threatening condition. ECG artifact caused by the 4to 6-Hz rest tremor of Parkinson disease (PD) can mimic a wide complex ventricular tachycardia (figure). Misinterpretation of ECG artifact can have grave consequences, including cardiac catheterization, administration of antiarrhythmics, and placement of automated implantable cardioverter-defibrillators.1 Tremo...
متن کامل'Doctor, treat your patient, not your monitor!' Tremor-induced ECG artefacts mimicking torsades de pointes.
To cite: Mirijello A, Fuorlo M, Addolorato G, et al. BMJ Case Rep Published online: [please include Day Month Year] doi:10.1136/bcr-2014204735 DESCRIPTION A 70-year-old woman, affected by congestive heart failure, diabetes and chronic obstructive pulmonary disease, was admitted to our internal medicine unit because of dyspnoea. On physical examination a high-amplitude right upper extremity trem...
متن کاملI-metaiodobenzylguanidine myocardial scintigraphy in Parkinson’s disease
Objectives—I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy is clinically used to estimate local myocardial sympathetic nerve damage in some forms of heart disease, autonomic nerve disturbance in diabetic neuropathy, and disturbance of the autonomic nervous system in neurodegenerative disease. In the present study, examinations were performed to clarify (1) the proportion of cardiac sym...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne
دوره 187 10 شماره
صفحات -
تاریخ انتشار 2015