Improved attenuation correction via appropriate selection of respiratory-correlated PET data
نویسندگان
چکیده
PURPOSE We propose a respiratory-correlated PET data processing method (called "BH-CT-based") based on breath-hold CT acquisition to reduce the smearing effect and improve the attenuation correction. The resulting images are compared with the ungated PET images acquired using a standard, free-breathing clinical protocol. METHODS The BH-CT-based method consisted of a list-mode acquisition with simultaneous respiratory signal recording. An additional breath-hold CT acquisition was also performed in order to define a tissue position from which PET events can be selected. A phantom study featured a 0.5-ml sphere (filled with 18F-fluorodeoxyglucose ((18)F-FDG) solution) pushed onto a rubber balloon (filled with (18)F-FDG solution and iodinated contrast agent). The feasibility of the BH-CT-based method was also assessed in two patients. RESULTS In the phantom study, the contrast-to-noise ratios (CNRs) were -1.6 for the Ungated volume and 5.1 for the BH-CT-based volume. For patients, CNRs were higher for BH-CT-based volumes than those for Ungated volumes (17.3 vs. 6.3 and 7.3 vs. 3.8, for patients 1 and 2, respectively). Bias-variance measurements were performed and yielded bias reduction of 40% with BH-CT-based. CONCLUSION The application of a BH-CT-based method decreases motion bias in PET images. This method resolves issues related to both PET-to-CT misregistration and erroneous attenuation correction and increases lesion detectability.
منابع مشابه
Impact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...
متن کاملComputed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...
متن کاملComparing approaches to correct for respiratory motion in NH3 PET-CT cardiac perfusion imaging
AIM Respiratory motion affects cardiac PET-computed tomography (CT) imaging by reducing attenuation correction (AC) accuracy and by introducing blur. The aim of this study was to compare three approaches for reducing motion-induced AC errors and evaluate the inclusion of respiratory motion correction. MATERIALS AND METHODS AC with a helical CT was compared with averaged cine and gated cine CT...
متن کاملRespiratory Motion Correction in Positron Emission Tomography
In this thesis, we develop a motion correction method to overcome the degradation of image quality introduced by respiratory motion in positron emission tomography (PET), so that diagnostic performance for lung cancer can be improved. Lung cancer is currently the most common cause of cancer death both in the UK and in the world. PET/CT, which is a combination of PET and CT, providing clinicians...
متن کاملCine CT for attenuation correction in cardiac PET/CT.
UNLABELLED In dual-modality PET/CT systems, the CT scan provides the attenuation map for PET attenuation correction. The current clinical practice of obtaining a single helical CT scan provides only a snapshot of the respiratory cycle, whereas PET occurs over multiple respiratory cycles. Misalignment of the attenuation map and emission image because of respiratory motion causes errors in the at...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer methods and programs in biomedicine
دوره 92 1 شماره
صفحات -
تاریخ انتشار 2008