Factors affecting carbon dioxide homeostasis during controlled ventilation with circle systems.

نویسندگان

  • C G Schoonbee
  • C M Conway
چکیده

An experimental lung model was used, with controlled ventilation, to determine the effect of different circle arrangements and varying ventilatory frequencies on the efficiency of carbon dioxide removal from a circle system without carbon dioxide absorption. Greater efficiency was found when fresh gas entered the system between the unidirectional inspiratory valve and the subject that when the fresh gas inlet was on the ventilator side of this valve. At any fresh gas flow and minute volume, efficiency was greater at low respiratory frequencies. Good correlations existed between carbon dioxide concentration in the model lung, fresh gas flow and minute ventilation when respiratory frequency was constant. Paradoxical results were obtained when minute volume was varied by changes in frequency at a constant tidal volume. The major cause of the various differences in performance has been ascribed to variations in the degree of mixing of fresh and expired gas within the system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of two ventilator systems using an infant lung model.

STANDARD adult circle systems (with adult ventilator bellows and carbon dioxide absorber) equipped with pediatric circuit hoses, rather than semiclosed partial rebreathing systems or specially designed pediatric circle systems (with small ventilator bellows and carbon dioxide canister), often are used to ventilate infants and children during administration of anesthesia. If adult circle ventila...

متن کامل

Anaesthesia Breathing Systems

Anaesthesia Breathing System (formerly known as anaesthesia Breathing Apparatus or Anaesthesia Breathing Circuit) is an interface between the anaesthetic machine and the patient. They evolved over 160 years from the open systems used by Morton to the present day closed systems using carbon dioxide absorbents. The main purpose of these systems is to deliver the required oxygen and anaesthetic ga...

متن کامل

Controlled respiration: standardization of ventilation.

THE technique of controlled respiration during anaesthesia was developed primarily to deal with respiratory inadequacy enforced on the patient by an open pneumothorax. This paper is concerned with developing means to adjust the volume of passive ventilation to a physiological level, the basis at present appearing to be entirely empirical. Originally, in order to institute controlled respiration...

متن کامل

Fresh gas requirements of an enclosed afferent reservoir breathing system during controlled ventilation in children.

An enclosed afferent reservoir breathing system (EAR) designed by Ohmeda was evaluated during anaesthesia with controlled ventilation in 104 healthy children. Carbon dioxide production and arterial carbon dioxide tension were measured in 12 children in order to determine the proportion of fresh gas (VF) involved in gas exchange. When the ratio of minute volume ventilation to fresh gas flow (VE:...

متن کامل

Pressure-controlled Volume Guaranteed Mode Improves Respiratory Dynamics during Laparoscopic Cholecystectomy: A Comparison with Conventional Modes

Background Pneumoperitoneum and altered positioning 1in laparoscopic cholecystectomy predispose to alterations in cardiorespiratory physiology. We compared the effects of volume controlled, pressure controlled, and the newly introduced pressure controlled-volume guaranteed ventilation (PCV-VG) modes of ventilation on respiratory mechanics and oxygenation during laparoscopic cholecystectomy. M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 53 5  شماره 

صفحات  -

تاریخ انتشار 1981