Classification of physiologically significant pumping states in an implantable rotary blood pump: effects of cardiac rhythm disturbances.
نویسندگان
چکیده
Methods of speed control for implantable rotary blood pumps (iRBPs) are vital for providing implant recipients with sufficient blood flow to cater for their physiological requirements. The detection of pumping states that reflect the physiological state of the native heart forms a major component of such a control method. Employing data from a number of acute animal experiments, five such pumping states have been previously identified: regurgitant pump flow, ventricular ejection (VE), nonopening of the aortic valve (ANO), and partial collapse (intermittent [PVC-I] and continuous [PVC-C]) of the ventricle wall. An automated approach that noninvasively detects such pumping states, employing a classification and regression tree (CART), has also been developed. An extension to this technique, involving an investigation into the effects of cardiac rhythm disturbances on the state detection process, is discussed. When incorporating animal data containing arrhythmic events into the CART model, the strategy showed a marked improvement in detecting pumping states as compared to the model devoid of arrhythmic data: state VE--57.4/91.7% (sensitivity/specificity) improved to 97.1/100.0%; state PVC-I--66.7/83.1% improved to 100.0/88.3%, and state PVC-C--11.1/66.2% changed to 0.0/100%. With a simplified binary scheme differentiating suction (PVC-I, PVC-C) and nonsuction (VE, ANO) states, suction was initially detected with 100/98.5% sensitivity/specificity, whereas with the subsequent improved model, both these states were detected with 100% sensitivity. The accuracy achieved demonstrates the robustness of the technique presented, and substantiates its inclusion into any iRBP control methodology.
منابع مشابه
Identification and classification of physiologically significant pumping states in an implantable rotary blood pump.
In a clinical setting it is necessary to control the speed of rotary blood pumps used as left ventricular assist devices to prevent possible severe complications associated with over- or underpumping. The hypothesis is that by using only the noninvasive measure of instantaneous pump impeller speed to assess flow dynamics, it is possible to detect physiologically significant pumping states (with...
متن کاملClassification of physiologically significant pumping states in an implantable rotary blood pump: patient trial results.
An integral component in the development of a control strategy for implantable rotary blood pumps is the task of reliably detecting the occurrence of left ventricular collapse due to overpumping of the native heart. Using the noninvasive pump feedback signal of impeller speed, an approach to distinguish between overpumping (or ventricular collapse) and the normal pumping state has been develope...
متن کاملIdentifying physiologically significant pumping state transitions in implantable rotary blood pumps used as left ventricular assist devices: an in-vivo study
The VentrAssist implantable rotary blood pump (IRBP) is a centrifugal pump that uses a hydrodynamic bearing to support its impeller. The pump is to be used as a left ventricular assist device (LVAD). Varying pump speed can control the degree of left ventricular assistance. By increasing impeller speed, it is possible to transition from the normal physiological state of ventricular ejection (VE)...
متن کاملControl Method of a Rotary Blood Pump for a Left Ventricular Assist Device
The aim of the investigation is to develop a control method of a rotary blood pump (RBP) to solve the following problems: estimation of the pump flow rate, achievement and maintaining of the desired flow level through the continuous adjustment of pump speed and prevention of adverse effects on the cardiovascular system. Results. Functional chart of RBP control consists of several units: a unit ...
متن کاملDevelopments in control systems for rotary left ventricular assist devices for heart failure patients: a review.
From the moment of creation to the moment of death, the heart works tirelessly to circulate blood, being a critical organ to sustain life. As a non-stopping pumping machine, it operates continuously to pump blood through our bodies to supply all cells with oxygen and necessary nutrients. When the heart fails, the supplement of blood to the body's organs to meet metabolic demands will deteriorat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Artificial organs
دوره 31 6 شماره
صفحات -
تاریخ انتشار 2007