Percutaneous closure of large VSD using a home-made fenestrated atrial septal occluder in 18-year-old with pulmonary hypertension

نویسندگان

  • Hacer Kamali
  • Turkay Saritas
  • Abdullah Erdem
  • Celal Akdeniz
  • Volkan Tuzcu
چکیده

BACKGROUND Hemodynamically significant muscular ventricular septal defects in children after the infantile period are a rare occurrence and ideal for transcatheter closure. In cases of severe concomitant pulmonary hypertension, it may be necessary to fenestrate the device. In this report, we present an 18-year old patient with a large mid-trabecular ventricular septal defect and severe pulmonary hypertension that underwent percutaneous closure of the defect with a home-made fenestrated atrial septal occluder. CASE PRESENTATION An 18-year-old female patient referred to us with complaints of dyspnea (NYHA score of 2-3). Physical examination revealed an apical rumble and a harsh second heart sound. Echocardiographic examination revealed a large mid-trabecular ventricular septal defect with bidirectional shunt and the widest diameter measuring 22 mm on 2D echocardiography. Left and right heart cavities were enlarged. Before and after the vasoreactivity test performed during cardiac catheterization, average aortic pressure was 65 → 86 mmHg, average pulmonary artery pressure: 58 → 73 mmHg, Qp/Qs: 1.6 → 3.2, PVR: 4.6 → 4.3 Wood/U/m2 and PVR/SVR: 0.5 → 0.2. On left-ventricular angiocardiogram, the largest end-diastolic defect diameter was 21 mm. The closure procedure was performed with transthoracic echocardiographic guidance, using a 24 mm Cera septal occluder and a 14 F sheath dilator to make a 4.5-5 mm opening. Measured immediately after the procedure and during cardiac catheterization one month later, average aortic pressure was 75 → 75 mmHg, average pulmonary artery pressure: 66 → 30 mmHg, Qp/Qs 1.5 → 1.4, PVR: 4.4 → 2.9 Wood/U/m2 and PVR/SVR: 0.4 → 0.2. Transthoracic echocardiographic examination performed 24 hours after the procedure showed a max 35-40 mmHg gradient between the left and right ventricles through the fenestration. After the procedure, we observed sporadic early ventricular systoles and a nodal rhythm disorder that started after approximately 12 hours and spontaneously reverted to normal 9 days later. CONCLUSION In patients with large ventricular septal defects, large atrial septal occluders may be used. In cases with risk of pulmonary vascular disease, a safer option would be to close the defect using a manually fenestrated device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Home-made fenestrated amplatzer occluder for atrial septal defect and pulmonary arterial hypertension

We report the management of a patient with secundum atrial septal defect (ASD) and severe pulmonary hypertension. A 65-year-old male with recently diagnosed atrial septal defect was referred to our centre for decompensated right heart failure with rest and exercise induced dispnea and severe pulmonary hypertension. Right heart catheterization confirmed a mean pulmonary pressure of about 55 mmHg...

متن کامل

Staged approach for the management of atrial septal defect in the presence of a small left ventricle and suprasystemic pulmonary pressure

A 29-year-old woman presented with a symptomatic large atrial septal defect, a small left ventricle with a modest left atrium, mild to moderate nonrheumatic mitral valve incompetence, an apex-forming very large right ventricle and suprasystemic pulmonary artery pressure. Following one year of preprocedural drug treatment to lower pulmonary hypertension, she underwent percutaneous closure of the...

متن کامل

Urgent Surgical Intervention for Embolized Cardiac Occluder Devices: A Case Series

Introduction: In this study, we sought to illustrate our experience in urgent surgical management for embolized cardiac septal occlude devices resulting from trans-catheter closure of atrial septal defect and ventricular septal defect. Mathrials and Methods: We retrospectively reviewed four patients aged 2–10 years who underwent urgent surgery due to cardiac septal occluder embolization between...

متن کامل

Integrated Percutaneous Atrial Septal Defect Occlusion and Pulmonary Balloon Valvuloplasty

Introduction: Atrial Septal Defect (ASD) is one of the most common congenital heart diseases during childhood. Today, ASD closure is done by occlutech device via cardiac catheterization. ASD repair with transcatheter technique has shown high closure rate. However, coexistence of severe pulmonary stenosis and large defect in atrial septum is rare. When these two problems coexist, the result is i...

متن کامل

Percutaneous closure of multiple atrial septal defects and patent ductus arteriosus during the same session.

An alternative to the surgical repair of secundum type atrial septal defects (ASD) and of patent ductus arteriosus (PDA) is transcatheter closure. However, there is limited information about the efficacy of using percutaneous devices to close multiple ASDs. An 8-year-old female patient was admitted to our hospital with a cardiac murmur. A large secundum multi-fenestrated ASD (17 mm, 4.5 mm, 3 m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014