Eye shield with removable lid.

نویسنده

  • G D Sturrock
چکیده

The prime cause of corneal damage in exposure keratitis is desiccation. This results from failure of the lids to cover the cornea for either mechanical or neurological reasons. In such cases the application of a closely-fitting shield affords considerable protection because a pocket of humid air is trapped in front of the cornea. Several simple occlusive shields have been described utilizing such varied materials as a watch crystal (Buller, 1874), x ray film (Sellinger, I947), thin plastic (Golden, I963), and silicone rubber (Deitz and Meldrum, I965). During the short-term treatment of acute exposure keratitis two conflicting requirements may arise. The eye must be hermetically covered yet readily accessible for observation and the instillation of drops. The two criteria are met by a simple cover made from a Cartella shield and a small plastic pillbox.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is padding necessary after cataract extraction?

The results of a prospective study to assess the value of padding eyes following cataract surgery are reported. A group of eyes dressed with a petroleum jelly mesh, gauze pad, and cartella shield were compared with a group dressed only with a cartella shield. Study of the eyes and lids before and after operation, including the taking of lid margin and fornix swabs for culture, suggested that th...

متن کامل

Assessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain

Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...

متن کامل

RADIOACTIVE WASTE MANAGEMENT ANALYSIS / MODEL REVISION RECORD Complete

ion of Models of Stress Corrosion Cracking of Drip Shield and Waste Package Outer Barrier and Hydrogen Induced Corrosion of Drip Shield TABLE OF CONTENTS Page 1. PU R P O SE ............................................................................................................................... 8 2. QUALITY ASSURANCE .............................................. 8 3. COMPUTER SOFTWARE AN...

متن کامل

Molecular endpoints of Ca2+/calmodulin- and voltage-dependent inactivation of Cav1.3 channels

Ca(2+)/calmodulin- and voltage-dependent inactivation (CDI and VDI) comprise vital prototypes of Ca(2+) channel modulation, rich with biological consequences. Although the events initiating CDI and VDI are known, their downstream mechanisms have eluded consensus. Competing proposals include hinged-lid occlusion of channels, selectivity filter collapse, and allosteric inhibition of the activatio...

متن کامل

تأثیر لاترال تارسورافی کوچک همراه با رسس عضله لواتور دربهبود رتراکشن پلک فوقانی در بیماران تیروئید اوفتالموپاتی

Introduction: Aim of the study was to determine the efficacy of minor lateral tarsorrhaphy in conjunction with levator muscle recession in thyroid ophthalmopathic patients with severe lid retraction in order to correct the temporal flare in these patients Methods: In a before-after clinical trial study, 22 eyelids of 12 patients with severe lid retraction underwent surgery by this method and t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 56 7  شماره 

صفحات  -

تاریخ انتشار 1972