Determination of corticosterone in rat and mouse plasma by gas chromatography-selected ion monitoring mass spectrometry.

نویسندگان

  • Pin Yen Shu
  • Shiu Huey Chou
  • Cheng Huang Lin
چکیده

A simple, highly sensitive and specific method based on gas-chromatography-selected ion monitoring (SIM) mass spectrometry has been developed for the quantitation of corticosterone in rat and mouse plasma. After extraction of the plasma with ethyl acetate, the residue was trimethy-silylated with pentafluorobenzyl hydroxylamine-trimethylsilyl (PFBO-TMS). Detection of the derivatives was accomplished by a quadruple mass spectrometer in the selected ion monitoring mode (m/z of 316, 648, 663 and 678). The detection limit of the assay was 0.1 pg on column. The results show that in the plasma of non-stressed animals, only minor amounts of corticosterone were found; whereas in the plasma of stressed animals, it was dramatically increased. The method developed here can be used to examine corticosterone levels as a marker of stress in rats and mice and may also be used for estimation of the effect of stress-release medications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Pharmacokinetics of Berberine, Palmatine and Jatrorrhizine in Rat Plasma after Oral Administration of Rhizoma coptidis and Zuojinwan Using Liquid Chromatography-Tandem Mass Spectrometry

A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of berberine, palmatine and jatrorrhizine in rat plasma. Target compounds, together with the internal standard (metronidazole), were extracted from rat plasma samples by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatography was carried out using a ...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Determination of Mebudipine in Human Plasma by Liquid Chromatography–tandem Mass Spectrometry

In previous studies, mebudipine, a dihydropyridine calcium channel blocker, showed a considerable potential to be used in cardiovascular diseases. The aim of the current study was to develop a valid method using reversed-phase high performance liquid chromatography coupled with electrospray ionization mass spectrometry to assay mebudipine in the human plasma. Separation was achieved on a Zorbax...

متن کامل

Comparative Pharmacokinetics of Berberine, Palmatine and Jatrorrhizine in Rat Plasma after Oral Administration of Rhizoma coptidis and Zuojinwan Using Liquid Chromatography-Tandem Mass Spectrometry

A selective and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the determination of berberine, palmatine and jatrorrhizine in rat plasma. Target compounds, together with the internal standard (metronidazole), were extracted from rat plasma samples by protein precipitation with acetonitrile-methanol (1:2, v/v). Chromatography was carried out using a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. B, Analytical technologies in the biomedical and life sciences

دوره 783 1  شماره 

صفحات  -

تاریخ انتشار 2003