BI-RADS lexicon for US and mammography: interobserver variability and positive predictive value.
نویسندگان
چکیده
PURPOSE To retrospectively evaluate interobserver variability between breast radiologists by using terminology of the fourth edition of the Breast Imaging Reporting and Data System (BI-RADS) to categorize lesions on mammograms and sonograms and to retrospectively determine the positive predictive value (PPV) of BI-RADS categories 4a, 4b, and 4c. MATERIALS AND METHODS Institutional review board approval was obtained; informed consent was not required. This study was HIPAA compliant. Ninety-four consecutive lesions in 91 women who underwent image-guided biopsy comprised 59 masses, 32 calcifications, and three masses with calcification. Five radiologists retrospectively reviewed these lesions. Each observer described each lesion with BI-RADS terminology and assigned a final BI-RADS category. Interobserver variability was assessed with the Cohen kappa statistic. A pathologic diagnosis was available for all 94 lesions; 30 (32%) were malignant and 64 (68%) were benign. Pathologic analysis of benign lesions was performed on tissue obtained with image-guided core-needle biopsy. In cases referred for excisional biopsy after needle biopsy because of atypia or discordance, final surgical pathologic analysis was used for correlation with imaging findings. PPV for category 4 or 5 lesions was determined for all readers combined. RESULTS For ultrasonographic (US) descriptors, substantial agreement was obtained for lesion orientation, shape, and boundary (kappa = 0.61, 0.66, and 0.69, respectively). Moderate agreement was obtained for lesion margin and posterior acoustic features (kappa = 0.40 for both). Fair agreement was obtained for lesion echo pattern (kappa = 0.29). For mammographic descriptors, moderate agreement was obtained for mass shape, mass margin, and calcification distribution (kappa = 0.48, 0.48, and 0.50, respectively). Fair agreement was obtained for calcification description (kappa = 0.32). Slight agreement was obtained for mass density (kappa = 0.18). Fair agreement was obtained for final assessment category (kappa = 0.28). PPVs of BI-RADS category 4 and 5 assignments were as follows: category 4a, six (6%) of 102; category 4b, 17 (15%) of 110; category 4c, 48 (53%) of 91; and category 5, 71 (91%) of 78. CONCLUSION Interobserver agreement with the new BI-RADS terminology is good and validates the US lexicon. Subcategories 4a, 4b, and 4c are useful in predicting the likelihood of malignancy.
منابع مشابه
173-177 Œ breast imaging.p65
OBJECTIVE: To review the literature about the positive predictive value of Breast Imaging Reporting and Data System (BI-RADS®) categories 3, 4 and 5. MATERIALS AND METHODS: A research was performed in the online Medline database, entering the terms “predictive value” and “BI-RADS”. Eleven studies were included in this review. RESULTS: The positive predictive values ranged respectively between 0...
متن کاملVariability and accuracy in mammographic interpretation using the American College of Radiology Breast Imaging Reporting and Data System.
BACKGROUND Several studies, which were limited by their small sample size and selection of difficult cases for review, have reported substantial variability among radiologists in interpretation of mammographic examinations. We have determined, in the largest study to date, intraobserver and interobserver agreement in interpreting screening mammography and accuracy of mammography by use of the A...
متن کاملInterobserver and Intraobserver Agreement of Sonographic BIRADS Lexicon in the Assessment of Breast Masses
BACKGROUND BI-RADS was first developed in 1993 for mammography and in 2003 it was redesigned for ultrasonography (US). If the observer agreement is high, the method used in the classification of lesion would be reproducible. OBJECTIVES The aim of this study is to evaluate the inter- and intraobserver agreement of sonographic BI-RADS lexicon in the categorization and feature characterization o...
متن کاملCharacterization of thyroid nodules using the proposed thyroid imaging reporting and data system (TI-RADS).
BACKGROUND The Thyroid Imaging Reporting and Data System (TI-RADS) was proposed based on a scheme similar to Breast Imaging Reporting and Data System (BI-RADS) lexicon used in breast lesions. The purpose of this study was to evaluate its interobserver variability and accuracy. METHODS We included 498 nodules in 437 patients undergoing thyroidectomy. Two endocrine surgeons and 2 endocrinologis...
متن کاملAccuracy of mammographic findings in breast cancer: correlation between BI-RADS classification and histological findings* Acurácia dos achados mamográficos do câncer de mama: correlação da classificação BI-RADS e achados histológicos
OBJECTIVE: The present study was aimed at evaluating the BI-RADS® classification accuracy in mammography. Additionally, the frequency of different findings was described and the interobserver agreement was evaluated. MATERIALS AND METHODS: Mammographic images of 115 patients were independently and blindly reviewed by two specialists in compliance with BI-RADS recommendations, and later compared...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 239 2 شماره
صفحات -
تاریخ انتشار 2006