Performance and Costs of Particle Air Filtration in HVAC Supply Airstreams
نویسندگان
چکیده
This paper uses a model, and data on particle size distributions, filter efficiencies, and particle deposition rates to estimate the reductions in the indoor mass concentrations of particles attainable from use of filters in HVAC supply airstreams. Additionally, the energy and total costs of the filtration options are estimated. Predicted reductions in cat and dust-mite allergen concentrations range from 20% to 60%. Increasing filter efficiencies above approximately ASHRAE Dust Spot 65% (MERV 11) does not significantly reduce predicted indoor concentrations of these allergens. For environmental tobacco smoke particles and outdoor fine mode particles, calculations indicate that relatively large, e.g., 80%, decreases in indoor concentrations are attainable with practical filter efficiencies. Increasing the filter efficiency above ASHRAE Dust Spot 85% (MERV 13) results in only modest incremental decreases in concentrations. Energy costs and total costs do not always increase for higher efficiency filters. Total estimated filtration costs of $0.70 to $1.80 per person per month are insignificant relative to salaries, rent, or health insurance costs.
منابع مشابه
Performance and costs of particle air filtration technologies.
This paper predicts the reductions in the indoor mass concentrations of particles attainable from use of filters in building supply airstreams and also from use of stand-alone fan-filter units. Filters with a wide efficiency range are considered. Predicted concentration reductions are provided for indoor-generated particles containing dust-mite and cat allergen, for environmental tobacco smoke ...
متن کاملارزیابی کارایی سیستم تهویه مطبوع یک ساختمان اداری در شهر تهران
Introduction: One of the factors influencing on indoor air quality of the buildings is performance of HVAC (heating, ventilation, and air conditioning) systems. These systems supply clean and odorless air, with temperature, humidity, and air velocity within comfort ranges for the residents. The aim of this study was to evaluate performance HVAC system in an administrative building in Tehran. .M...
متن کاملApplication of Solar Thermal Collectors to Improve the Energy Performance of the Fresh Air HVAC Systems
In the preset study, the performance of a solar assisted heating, ventilation and air conditioning (HVAC) system in an operating theater building was studied. The yearly performances of the existing HVAC system and the system with the added solar collectors were simulated in terms of energy consumption and provided air conditions using a transient system simulation software (TRNSYS). In t...
متن کاملDesign and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study
In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...
متن کاملEstimates of HVAC filtration efficiency for fine and ultrafine particles of outdoor origin
This work uses 194 outdoor particle size distributions (PSDs) from the literature to estimate single-pass heating, ventilating, and air-conditioning (HVAC) filter removal efficiencies for PM2.5 and ultrafine particles (UFPs: <100 nm) of outdoor origin. The PSDs were first fitted to tri-modal lognormal distributions and then mapped to size-resolved particle removal efficiency of a wide range of ...
متن کامل