Analysis at the Atomic Level: The Atom Probe Field-Ion Microscope
نویسنده
چکیده
Figure 2. Angular distributions of inelastic scattering around the undiffracted beam and around a beam diffracted through an angle a. The shaded area represents the contribution from the diffracted beam to the intensity collected by an on-axis aperture of semi-angle A3. [6] Egerton, R. F., Electron Energy Loss Spectroscopy in the Electron Microscope, Plenum Press, New York (1986). [7] Steele, J. D., Titchmarsh, J. M., Chapman, J. N., and Paterson, J. H., Ultramicroscopy 17, 273 (1985), [8] Leapman, R. D., and Swyt, C. R., Removal of Plural Scattering in Electron Energy Loss Spectra from Organic Samples: A New Approach, Microbeam Analysis (1987) p. 273. [9] Zaluzec, N. J., Spectral Processing and Quantitative Analysis in Electron Energy Loss Spectroscopy Using a Digital Filter Technique, Analytical Electron Microscopy (1987). [10] Bourdillon, A. J., and Stobbs, W. M., Ultramicroscopy 17, 147 (1985). [11] Zaluzec, N. J., The Influence of Specimen Thickness in Quantitative Energy-Loss Spectroscopy, 41st Ann. Proc. Electron Microsc. Soc. Am., p. 388. [12] Egerton, R. F., Quantitative Microanalysis by Electron Energy Loss Spectroscopy: The Current Status, Scanning Electron Microscopy (1984) part 1, p. 505. [131 Egerton, R. F., SIGMAL: A Program for Calculating LShell Ionization Cross Sections, 39th Ann, Proc. Electron Microsc. Soc. Am. (1979) p. 198. [14] Rez, P., and Ahn, C., Comparison of Theoretical EELS Edges with Experimental Data, Analytical Electron Microscopy (1984) p. 294. [15] Malis, T., and Titchmarsh, J. M., A k-Factor Approach to EELS Analysis, EMAG 1985, Institute of Physics, Bristol, U.K. [16] Hofer, F., Ultramicroscopy 21, 63 (1987). [17] Craven, A. J., and Buggy, T. W., Ultramicroscopy 7, 27 (1981). [18] Thomas, L. E., Ultramicroscopy 18, 173 (1985).
منابع مشابه
Localizing of a Four-Level Atom via Absorption Spectrum
We propose a scheme for localizing an atom in a four-level configuration inside a classical standing wave field, conditioned upon the measurement of frequency of a weak probe field. In the classical standing wave field, the interaction between the atom and the field is position dependent due to the Rabi-frequency of the driving field. Hence, as the absorption frequency of the probe field is mea...
متن کاملFocused ion beam preparation of atom probe specimens containing a single crystallographically well-defined grain boundary.
Needle-shaped atom probe specimens containing a single grain boundary were produced using the focused ion beam (FIB) of a two-beam FIB/SEM (scanning electron microscope) system. The presented specimen preparation approach allows the unprecedented study of a grain boundary which is well characterised in its crystallographic orientation by means of the field ion microscope (FIM) and the tomograph...
متن کاملEffect of Field-evaporation Rate on Quantitative Atom-probe Analysis
The effects of field-evaporation rate on the quantitative chemical analysis of materials by atom-probe field-ion microscopy are considered. Examples of erroneously high measured values of the Ti concentration in Mo-1.0 at.% Ti and Mo-1.0 at.% Ti-0.08 at.% Zr (TZM) alloys are presented and the cause is shown to have been due to a high field-evaporation rate. The basic arguments used to explain t...
متن کاملNanoscale Microstructural Analyses by Atom Probe Field Ion Microscopy
Recent progress in atom probe field ion microscopy (APFIM) and its applications to nanoscale microstructural studies of metallic materials are reviewed. By employing a three dimensional atom probe (3DAP), it is possible to map out elemental distributions in the real space with almost an atomic resolution, and chemical analysis of interfaces and nanoparticles can be made with improved accuracy i...
متن کاملFocused ion beam sample preparation for atom probe tomography
Atom Probe (AP) tomography is maturing into a routine method for the atomic resolution compositional analysis of metals, semiconductors and some polymers. This is often combined with a Transmission Electron Microscope (TEM) analysis of the same region of interest. The Focused Ion Beam (FIB) microscope has evolved as an essential tool for site and orientation specific sample preparation for such...
متن کاملSensitivity analysis of a caliper formed atomic force microscope cantilever based on a modified couple stress theory
A relationship based on the modified couple stress theory is developed to investigate the flexural sensitivity of an atomic force microscope (AFM) with assembled cantilever probe (ACP). This ACP comprises a horizontal cantilever, two vertical extensions and two tips located at the free ends of the extensions which form a caliper. An approximate solution to the flexural vibration problem is obta...