Non-contact mapping to guide catheter ablation of untolerated ventricular tachycardia.
نویسندگان
چکیده
AIMS The role of a novel non-contact mapping system (ESI 3000, Endocardial Solutions) to guide radiofrequency catheter ablation of untolerated ventricular tachycardia was investigated in 17 patients; 11 with prior myocardial infarction, three with arrhythmogenic right ventricular dysplasia, and three with idiopathic dilated cardiomyopathy. METHODS Twenty-seven monomorphic ventricular tachycardias were induced (mean cycle 320+/-60 ms, range 230-450 ms), mapped for 15-20 s, and terminated by overdrive pacing or DC shock. Off-line analysis of isopotential activation mapping was performed to identify the diastolic pathway and/or the exit point of the ventricular tachycardia reentry circuit. Radiofrequency current was applied to create a line of block across the diastolic pathway or around the exit point. RESULTS All 27 ventricular tachycardias were mapped with the non-contact system. The endocardial exit point (-7+/-15 ms before QRS onset) was defined in 21/21 postinfarction ventricular tachycardias, in 3/3 arrhythmogenic right ventricular dysplasia and in 1/3 idiopathic dilated cardiomyopathy ventricular tachycardias, respectively. The diastolic pathway (earliest endocardial diastolic activity: -65+/-49 ms before QRS onset) was identified in 17/21 postinfarction ventricular tachycardias, in 1/3 arrhythmogenic right ventricular dysplasia and in 1/3 idiopathic dilated cardiomyopathy ventricular tachycardias, respectively. Catheter ablation was performed in 25/27 ventricular tachycardias (93%) in 15/17 patients (88%): 16/25 ventricular tachycardias (64%) were successfully ablated in 10/17 patients (59%). Catheter ablation was not performed in two patients or proved unsuccessful in five patients. At a follow-up of 15+/-5 months, there was no recurrence of documented ventricular tachycardia in all 10 patients with successful catheter ablation; in two of them a previously non-documented ventricular tachycardia occurred. A high recurrence of ventricular tachycardia was observed in patients with a failed procedure (5/7: 71%). No major complication or death occurred. CONCLUSIONS Non-contact mapping can be effectively used to map and guide radiofrequency catheter ablation of untolerated ventricular tachycardias. Given the favourable acute and clinical long-term results, this approach proves to be more effective in patients with postinfarction ventricular tachycardias, in comparison to patients with arrhythmogenic right ventricular dysplasia and idiopathic dilated cardiomyopathy.
منابع مشابه
Radiofrequency catheter ablation of various kinds of arrhythmias guided by virtual electrograms using a noncontact, computerized mapping system.
Three-dimensional visualization of cardiac activation has become important for providing further insights into the pathophysiological mechanisms of arrhythmias and to increase the efficacy of catheter ablation. The noncontact mapping system enables a single-beat analysis of the reconstructed geometry of the cardiac chamber. In 8 patients with various kinds of arrhythmias (3 with atrial flutter,...
متن کاملPossibility of contact force monitoring during catheter ablation of ventricular tachycardia
Nowadays, electroanatomical mapping system are widely used to clarify arrhythmic substrates and identify the target of ablation not only in patients with supraventricular tachycardia or atrial fibrillation but also ventricular tachycardia. To achieve good results in the procedure, it is important to obtain precise mapping information and to deliver adequate radiofrequency energy. Although it is...
متن کاملShort-term results of substrate mapping and radiofrequency ablation of ischemic ventricular tachycardia using a saline-irrigated catheter.
OBJECTIVES We evaluated the safety and acute procedural efficacy of a combined electrophysiologic and anatomic approach to ablation of all inducible ventricular tachycardias (VT) during sinus rhythm using an irrigated radiofrequency (RF) ablation catheter. BACKGROUND Ventricular tachycardia associated with chronic myocardial infarction (MI) is frequently hemodynamically intolerable and associ...
متن کاملMapping and ablation of ventricular tachycardia guided by virtual electrograms using a noncontact, computerized mapping system.
OBJECTIVES The purpose of this study was to describe a computerized mapping system that utilizes a noncontact, 64 electrode balloon catheter to compute virtual electrograms simultaneously at 3,360 left ventricular (LV) sites and to assess the clinical utility of this system for mapping and ablating ventricular tachycardia (VT). BACKGROUND Mapping VT in the electrophysiology laboratory convent...
متن کاملFeasibility of a noncontact catheter for endocardial mapping of human ventricular tachycardia.
BACKGROUND Catheter ablation of ventricular tachycardia (VT) is limited by difficulty in identifying suitable sites for ablation. This study assesses use of a system capable of simultaneous endocardial mapping of the human left ventricle to map and guide radiofrequency (RF) catheter ablation of VT. METHODS AND RESULTS A catheter-mounted noncontact multielectrode array was used to reconstruct ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal
دوره 23 9 شماره
صفحات -
تاریخ انتشار 2002