Visualization of Defibrillation Simulation Using Multiple Transthoracic Electrodes

نویسندگان

  • Joseph Qualls
  • David J. Russomanno
  • Amy de Jongh Curry
  • Deepika Konakanchi
چکیده

DefibViz is a software tool for defibrillation simulation and the visualization of the resulting voltage gradient induced throughout the human heart and torso. This paper presents an extension to DefibViz that provides functionality for the interactive placement of multiple sets of transthoracic electrodes of varying shape, size, and applied voltage. Such a tool may provide biomedical engineers with additional insight into the efficacy of multi-electrode configurations as compared to the single pair of electrodes used in conventional defibrillators.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of epicardial patch electrodes on transthoracic defibrillation.

To improve survival rates in patients undergoing surgical ablative procedures for malignant ventricular tachycardia (VT), a frequent practice is to implant epicardial patch electrodes at the time of map-guided surgery. After operation, patients with inducible VT often receive an automatic internal cardioverter/defibrillator (AICD) implant, whereas patients with noninducible VT usually do not. I...

متن کامل

Transthoracic defibrillation: effect of sternotomy on chest impedance.

The purpose of this study was to determine the effect of sternotomy on transthoracic impedance, a major determinant of current flow and defibrillation success. Transthoracic impedance was determined by using a validated test-pulse technique that does not require actual shocks. Seventeen patients undergoing median sternotomy were studied prospectively. Transthoracic impedance was determined befo...

متن کامل

Intrathoracic current flow during transthoracic defibrillation in dogs. Transcardiac current fraction.

To achieve transcardiac threshold current during transthoracic defibrillation, a considerably larger current must be delivered to the thorax to compensate for the shunting effect of the lungs, the thoracic cage, and other elements of the torso. This shunting effect is thus an important determinant of transthoracic defibrillation threshold and can be quantified by the transcardiac current fracti...

متن کامل

WORKSHEET for Evidence-Based Review of Science for Emergency Cardiac Care Worksheet author(s)

Search strategy (including electronic databases searched). DRAJER: Several search strategies were used for each data base. Only those with maximal hits were considered Embase “defibrillation” AND “pads” AND “impedance” as text words (all fields): 31 hits Embase “defibrillation” AND “pads” AND [<1966-2010]/py: 85 hits PubMed “defibrillation” AND “electrode pads” as text words (all fields): 52 hi...

متن کامل

Relation between transcardiac and transthoracic current during defibrillation in humans.

Conceptually, transthoracic defibrillation threshold current can be considered a function of at least two quantities. It is directly proportional to the transcardiac threshold current and inversely proportional to the transcardiac current fraction (FC) or the ratio of transcardiac and transthoracic current. Although experimental and theoretical estimates of FC have been as high as 45%, previous...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008