Validation of simplified dosimetry approaches in ⁸⁹Zr-PET/CT: the use of manual versus semi-automatic delineation methods to estimate organ absorbed doses.

نویسندگان

  • N E Makris
  • F H P van Velden
  • M C Huisman
  • C W Menke
  • A A Lammertsma
  • R Boellaard
چکیده

PURPOSE Increasing interest in immuno-positron emission tomography (PET) studies requires development of dosimetry methods which will provide accurate estimations of organ absorbed doses. The purpose of this study is to develop and validate simplified dosimetry approaches for (89)Zirconium-PET (Zr-PET)/computed tomography (CT) studies. METHODS Five patients with advanced colorectal cancer received 37.1 ± 0.9 MBq (89)Zr-cetuximab within 2 h after administration of a therapeutic dose of 500 mg m(-2) cetuximab. PET/CT scans were obtained 1, 24, 48, 94, and 144 h post injection. Volumes of interest (VOIs) were manually delineated in lungs, liver, spleen, and kidneys for all scans, providing a reference VOI set. Simplified manual VOIs were drawn independently on CT scans using larger voxel sizes. The transformation of VOIs based on rigid and/or nonrigid registrations of the first CT scan (CT1) onto all successive CT scans was also investigated. The transformation matrix obtained from each registration was applied to the manual VOIs of CT₁ to obtain VOIs for the successive scans. Dice similarity coefficient (DSC) and Hausdorff distance were used to assess the performance of the registrations. Organ total activity, organ absorbed dose, and effective dose were calculated for all methods. RESULTS Semi-automatic delineation based on nonrigid registration showed excellent agreement for lungs and liver (DSC: 0.90 ± 0.04; 0.81 ± 0.06) and good agreement for spleen and kidneys (DSC: 0.71 ± 0.07; 0.66 ± 0.08). Hausdorff distance ranged from 13 to 16 mm depending on the organ. Simplified manual delineation methods, in liver and lungs, performed similarly to semi-automatic delineation methods. For kidneys and spleen, however, poorer accuracy in total activity and absorbed dose was observed, as the voxel size increased. Organ absorbed dose and total activity based on nonrigid registration were within 10%. The effective dose was within ±3% for all VOI delineation methods. CONCLUSIONS A fast, semi-automatic, and accurate delineation method based on nonrigid registration was developed for determination of organ absorbed and effective dose in (89)Zr-PET/CT studies which may also be applied to other long-lived radionuclide PET/CT studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

4 PET / CT derived whole body and bone marrow dosimetry of 89 Zr - cetuximab

PET/CT imaging allows for image based estimates of organ and red marrow (RM) residence times. The aim of this study was to derive PET/CT based radiation dosimetry for Zr-cetuximab, with special emphasis on determining RM absorbed dose. Methods: Seven patients with colorectal cancer received 36.9 ± 0.8 MBq Zr-cetuximab within 2 h after administration of a therapeutic dose of 500 mg⋅m of cetuxima...

متن کامل

An automatic delineation method for bone marrow absorbed dose estimation in 89Zr PET/CT studies

BACKGROUND The study aims to develop and validate an automatic delineation method for estimating red bone marrow (RM) activity concentration and absorbed dose in (89)Zr positron emission tomography/computed tomography (PET/CT) studies. Five patients with advanced colorectal cancer received 37.1 ± 0.9 MBq [(89)Zr] cetuximab within 2 h after administration of a therapeutic dose of 500 mg m(-2) un...

متن کامل

The comparison of serial SPECT-CT imaging to estimate absorbed dose to the organ at risk from peptide receptor radionuclide therapy dosimetry

Introduction: In Peptide Receptor Radionuclide Therapy (PRRT), the administration of radionuclide such as Lu-177 label with a pharmaceutical agent useful to destroy the lesion. The amount of Lu-177 radioactivity administered to the patients is still not standardize and generally not more than 7.4 GBq per session due to the patient’s safety issues. The first cycle of Lu-177 is a...

متن کامل

Estimate bowtie filter shape in PET/CT scan with TLD

Introduction: The CT machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. Configuration of this bowtie filter is complex and its geometry is often not available in detail. It causes the CT dose index (CTDI) be with the different values in measurement versus Monte Carlo simulation studies and other analytical calculations. It is important esp...

متن کامل

Estimation of Absorbed and Effective Doses in Organs through Computed Tomography Examinations Using Automatic Exposure Control and Fixed Tube Current Techniques: A Phantom Case Study

Introduction: The study aimed to assess absorbed and effective doses in organs through computed tomography (CT) examinations using automatic exposure control (AEC) and fixed tube current (FTC) techniques. Material and Methods: Scanning parameters were obtained for routine adult CT examinations and used to estimate the organ absorbed and effec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 41 10  شماره 

صفحات  -

تاریخ انتشار 2014