Actinide bioimaging in tissues: Comparison of emulsion and solid track autoradiography techniques with the iQID camera
نویسندگان
چکیده
This work presents a comparison of three autoradiography techniques for imaging biological samples contaminated with actinides: emulsion-based, plastic-based autoradiography and a quantitative digital technique, the iQID camera, based on the numerical analysis of light from a scintillator screen. In radiation toxicology it has been important to develop means of imaging actinide distribution in tissues as these radionuclides may be heterogeneously distributed within and between tissues after internal contamination. Actinide distribution determines which cells are exposed to alpha radiation and is thus potentially critical for assessing absorbed dose. The comparison was carried out by generating autoradiographs of the same biological samples contaminated with actinides with the three autoradiography techniques. These samples were cell preparations or tissue sections collected from animals contaminated with different physico-chemical forms of actinides. The autoradiograph characteristics and the performances of the techniques were evaluated and discussed mainly in terms of acquisition process, activity distribution patterns, spatial resolution and feasibility of activity quantification. The obtained autoradiographs presented similar actinide distribution at low magnification. Out of the three techniques, emulsion autoradiography is the only one to provide a highly-resolved image of the actinide distribution inherently superimposed on the biological sample. Emulsion autoradiography is hence best interpreted at higher magnifications. However, this technique is destructive for the biological sample. Both emulsion- and plastic-based autoradiography record alpha tracks and thus enabled the differentiation between ionized forms of actinides and oxide particles. This feature can help in the evaluation of decorporation therapy efficacy. The most recent technique, the iQID camera, presents several additional features: real-time imaging, separate imaging of alpha particles and gamma rays, and alpha activity quantification. The comparison of these three autoradiography techniques showed that they are complementary and the choice of the technique depends on the purpose of the imaging experiment.
منابع مشابه
Track detection on the cells exposed to high LET heavy-ions by CR-39 plastic and terminal deoxynucleotidyl transferase (TdT)
Background: The fatal effect of ionizing radiation on cells depends on Linear Energy Transfer (LET) level. The distribution of ionizing radiation is sparse and homogeneous for low LET radiations such as X or γ, but it is dense and concentrated for high LET radiation such as heavy-ions radiation. Material and Methods: Chinese hamster ovary cells (CHO-K1) were exposed to 4 Gy Fe-ion 2000 keV/...
متن کاملAutoradiography with the Electron Microscope
Autoradiographic techniques for use with the electron microscope have been developed and considerably improved in recent years. A review of this historical development is given by Meek and Moses (14), and a theoretical analysis of the problems involved by Pelc (17) and Caro (4). In this paper, we describe a method for preparing autoradiographic specimens, using a new, fine-grained emulsion and ...
متن کاملAUTORADIOGRAPHY WITH THE ELECTRON MICROSCOPE A Procedure for Improving Resolution, Sensitivity, and Contrast
Autoradiographic techniques for use with the electron microscope have been developed and considerably improved in recent years. A review of this historical development is given by Meek and Moses (14), and a theoretical analysis of the problems involved by Pelc (17) and Caro (4). In this paper, we describe a method for preparing autoradiographic specimens, using a new, fine-grained emulsion and ...
متن کاملCOMPUTER SIMULATION OF FLUID FLOW FILLING DURING MOLD USING FINITE VOLUME METHOD
In this investigation, ^5 2-D Finite Volume Method (FVM) with unstructured triangular mesh is developed to simulate the mould filling process. The simulation of fluid flow and track of free surface is based on the Marker And Cell (MAC) technique. This technique has capability ofhandling the arbitrary curved solid boundaries in the casting processes. In order to verify the computational results ...
متن کاملمقایسه متغیرهای منتخب کینماتیکی استارت تکپای جلو وزن و عقب وزن شناگران پسر نخبه
Objective: Over recent years, due to scientific advances in various aspects of sport, rapid development and improvement has taken place in sport performance standards as well as athletes' performance. In the swimming tournaments, on-time and correct start, plays an important role in the success of swimmers, especially speed swimmers. The aim of this study was comparising selected kinematic vari...