Sealed Gravitational Capillary Viscometry of Dimethyl Ether and Two Next-Generation Alternative Refrigerants

نویسندگان

  • Dylan S. Cousins
  • Arno Laesecke
چکیده

The viscosities of dimethyl ether (DME, C2H6O) and of the fluorinated propene isomers 2,3,3,3-tetrafluoroprop-1-ene (R1234yf, C3H2F4) and trans-1,3,3,3-tetrafluoropropene (R1234ze(E)) were measured in a combined temperature range from 242 K to 350 K at saturated liquid conditions. The instrument was a sealed gravitational capillary viscometer developed at NIST for volatile liquids. Calibration and adjustment of the instrument constant were conducted with n-pentane. The repeatability of the measurements was found to be approximately 1.5 %, leading to a temperature-dependent estimated combined standard uncertainty of the experimental data between 5.7 % at 242 K for dimethyl ether and 2.6 % at 340 K for R1234yf. The measurements were supplemented by ab initio calculations of the molecular size, shape, and charge distributions of the measured compounds. The viscosity results for dimethyl ether were compared with literature data. One other data set measured with a sealed capillary viscometer and exceeding the present results by up to 7 % could be reconciled by applying the vapor buoyancy correction. Then, all data agreed within the estimated uncertainty of the present results. Viscosities for the fluorinated propene isomers deviate up to 4 % from values predicted with the NIST extended corresponding-states model. The viscosities of the two isomers do not scale with their dipole moments. While the measured viscosity of R1234ze(E) with the lower dipole moment is close to that of R134a, the refrigerant to be replaced, that of R1234yf with the higher dipole moment is up to 25 % lower. The viscosity of dimethyl ether is compared with those of water and methanol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Study of the Eco-friendly Hydrofluoroolefins and Dimethyl-ether Refrigerants in Refrigeration Systems

*Engr. Dr. Bukola Olalekan Bolaji ([email protected]), Department of Mechatronics Engineering, Federal University of Agriculture, College of Engineering, P.M.B. 2240, Abeokuta, Nigeria.

متن کامل

Effect of Initial Temperature and EGR on Combustion and Performance Characteristics of Homogenous Charge Compression Ignition Engine Fueled with Dimethyl Ether

Homogeneous Charge Compression Ignition (HCCI) combustion is a pioneer method of combustion in which pre-mixed fuel and oxidizer (typically air) are compressed to the point of auto-ignition. HCCI engines can operate with most alternative fuels, especially, dimethyl ether (DME) which has been tested as a possible diesel fuel due to its simultaneously low NOx and PM emissions. In this paper a ...

متن کامل

Research and Assessment of Applying Dimethyl Ether “DME” Extracted from Natural Gas “Ng”, on Diesel Engine as a Clean Fuel (TECHNICAL NOTE)

Due to the shortage of liquid hydrocarbon fuels for compression ignition engines, researchers have constantly been looking for alternative fuels. Recently, dim ethyl ether (DME) with its interesting properties, such as high cetane number and low exhaust emission has drawn a lot of interst as a suitable fuel for diesel engines. The main objective of this study was to assess the potentials and fe...

متن کامل

Mix Design Selection For Old and New Generation of SuprePlasticizers

Determination the optimal mix design plays an important role in order to gain the maximum characteristic strength. This research was conducted as a case study for Manjil tunnel project located in Qazvin-Rasht highway. For this purpose, 18 concrete mix designs were prepared at the study phase of the project with specifications such as conventional water-to-cement ratios of 0.4, 0.5 and 0.6, the ...

متن کامل

Experimental Performance of Window Air Conditioner Using Alternative Refrigerants with Different Configurations of Capillary Tube A Review

This review paper presents the work of various researches on the performance of capillary tube ,used in air conditioners with various refrigerants. Research carried out by different authors uses different type of capillary tubes (straight, twisted, coiled) in different length and diameter. they determined various parameters like coefficient of performance (COP),cooling capacity, energy efficien...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 117  شماره 

صفحات  -

تاریخ انتشار 2012