Cross-sectional echocardiography. II. Analysis of mathematic models for quantifying volume of the formalin-fixed left ventricle.
نویسندگان
چکیده
Cross-sectional echocardiography was used to quantify volume in 21 canine left ventricles that were fixed in formalin and immersed in mineral oil. Area, length and diameter measurements were obtained from short- and long-axis cross-sectional images of the left ventricle and volume was calculated by seven mathematic models. Calculated volume was then compared, by linear regression and percent error analyses, with fluid volume of the left ventricle, obtained by filling the chamber with a known amount of fluid. Volumes ranged from 13-146 ml. Mathematic models using short-axis area and long-axis length gave higher correlation coefficients (r = 0.982 and r = 0.969) and lower mean errors (10-20%) than standard formulas previously used for M-mode echo and angiography. Thus, short-axis area analysis with cross-sectional echocardiography is well-suited for quantifying left ventricular volumes in dogs.
منابع مشابه
Quantifying Volume of the Formalin-fixed Left Ventricle
were fixed in formalin and immnersed in mineral oil. Area, length and diameter measurements were obtained from shortand long-axis cross-sectional images of the left ventricle and volume was calculated by seven mathematic models. Calculated volume was then compared, by linear regression and percent error analyses, with fluid volume of the left ventricle, obtained by filling the chamber with a kn...
متن کاملCross-sectional echocardiography. I. Analysis of mathematic models for quantifying mass of the left ventricle in dogs.
Cross-sectional echocardiography was used to quantify left ventricular mass noninvasively in 21 dogs. Short- and long-axis cross-sectional images of the left ventricle were reproducibly traced at endocardial and epicardial borders during stop-motion video-tape replay. We used area, length and diameter measurements to calculate left ventricular mass by seven mathematic models, including the stan...
متن کاملEvaluation of Cardiac Function in Patients with Brain Death using Advanced Hemodynamic Monitoring
Background: Studies on hemodynamic changes in brain death are in vitro and in animal studies. And very few studies have been done on the hemodynamic changes of brain death. The aim of this study was to use advanced hemodynamic monitoring with echocardiography for evaluation of donated heart and to evaluate the moment by moment brain death patients with advanced hemodynamic monitoring tools and ...
متن کاملSERVO METHOD FOR BP DETERMINATION/Aaslid and Brubakk
left ventricle in dogs. Circulation 60: 1104, 1979 14. Eaton LW, Maughan WL, Weiss JL: Accurate volume determination in the isolated ejecting canine heart from a limited number of two-dimensional echocardiographic cross-sections. (abstr) Am J Cardiol 45: 470, 1980 15. Helak J, Reichek N, Pearlman E, Weber K, Pietra G, Kastor JA: Quantitation of human left ventricular mass and volume by cross-se...
متن کاملCross-sectional Echocardiography 1. Analysis of Mathematic Models for Quantifying Mass of the Left Ventricle in Dogs
H atle L. Brubakk A, Tromsdal A, Angelsen B: Non-invasive assessment of pressure drop in mitral stenosis by Doppler ultrasound. Br Heart J 40: 131. 1978 3. Libanotf AJ, Rodbard S: Evaluation of the severity of mitral stenosis and regurgitation. Circulation 33: 218, 1966 4. Libanoff AJ, Rodbard S: Atrioventricular pressure half-time. Mleasure of mitral valve orifice area. Circulation 38: 144, 19...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 61 6 شماره
صفحات -
تاریخ انتشار 1980